CM501 Clean Room Gas Monitor
Production Information

|
As the degree of integration of LSI increases as well as large scaled FPD production is driving forward, removal of gaseous contaminants such as ammonia and acid gases in clean room has become an important issue. To cope with this requirement, monitoring of air borne contaminants and periodic check of chemical performance at chemical filter is vital measure. The CM501 clean room gas monitor measures ammonia and acid gases continuously at high sensitivity by utilizing a diffusion scrubber and an ion chromatograph. Diffusion scrubber is to absorb ammonia/acid gases in pure water. Then these are analyzed with an ion chromatograph. The CM501 realize contamination-free, on-line air borne monitoring. Optional multi-stream type (16 points) is also available. |
| Bulletin |
| General Specification |
Features
| * | Ammonia gas is measured at a sensitivity of 0.01 μg/m3. |
| * | Acidic gases (hydrogen chloride, phosphoric acid, sulfur dioxide, etc.) are measured at the same sensitivity of 0.02 μg/m3. |
| * | Ion chromatography, a highly reliable analyzing technique is used. |
| * | A unique diffusion scrubber technique minimizes the contamination of samples.. |
| * | Eluent consumption is minimal and replacement of eluent is required only once a month. |
| * | The results are monitored on a trend graph from a work station. |
| * | Filterlife prediction software is available as a standard feature. |
| * | Samples of up to 16 points are measured (optional). |
Specifications 
| Measurement |
|
|
| Gas collection method | Diffusion scrubber system | |
| Analysis method | Ion chromatography | |
| Measuring range | 0 to 50 μg/m3 | |
| Minimum detection limit | 0.01 μg/m3 (Ammonia) , 0.02mg/m3 ( Acid gas) | |
| Measurement cycle | Minimum 35 min. cycle. | |
| Measuring points | One point or up 16 points (optional) | |
| Calibration | Calibration using standard solutions, automatic calibration | |
| External contact input | Measuring stream skip signal, external alarm signal, external alarm reset signal | |
| External contact output | Abnormal concentration signal, system alarm signal, measuring stream signal, re-measurement signal, liquid leakage signal, alarm buzzer signal, alarm light signal | |
| Power supply | 100 to 120 V AC, 50/60 Hz or 200 to 240 V AC, 50/60 Hz | |
| Weight | Approx. 170kg (except for chemical solution, workstation, and pure water system.) |