CM505 Clean Room Gas Monitor (Discontinued)
Model CM505 (Discontinued)
Clean Room Gas Monitor for Semiconductor Plants
Product Information

As the degree of integration of LSI increases as well as large scaled FPD production is driving forward, removal of gaseous contaminants such as ammonia and acid gases in clean room has become an important issue. To cope with this requirement, monitoring of air borne contaminants and periodic check of chemical performance is vital measure. Typical test method conducted for this purpose is impinger method. However, conventional impinger method has problem of long measuring time and cross contamination by the operator.
The CM505 clean room gas monitor realize contamination-free, on-line air borne monitoring with impinger method with measuring time of 1hour. Optional multi-stream type (16 points) is also available. The system can monitor both Ammonia (or cations) and Acid gases (Anions) depend on the requirement.
Features
| * | Gas collection is done by impinger thus both gaseous and particle/mist contaminants are collected. |
| * | Ammonia gas is measured at a sensitivity of 0.01 μg/m3. |
| * | Acidic gases (HCl, SO2, NO2,) are measured at the same sensitivity of 0.02 μg/m3. |
| * | The system can monitor Boron, F-, and Organic Acid (CH3COO-, HCOO-) depend on the requirement. |
| * | Fully automated system and un-manned measurement. |
| * | Ion chromatography, a highly reliable analyzing technique is used. |
| * | Optional chemical filter life production software and multi-strem swicthing type (up to 16) are available. |
Specifications 
| Measurement |
|
|||||
| Gas collection method | Impinger method | |||||
| Analysis method | Ion chromatography | |||||
| Measuring range |
|
|||||
| Minimum detection limit |
|
|||||
| Measurement cycle | Mini60 min. or 90 min. | |||||
| Measuring points | One point or up to 16 points (optional) | |||||
| Calibration | Calibration using standard solutions, automatic calibration | |||||
| External contact input | Measuring stream skip signal, external alarm signal, external alarm reset signal | |||||
| External contact output | Abnormal concentration signal (for every stream, relay contact), system alarm signal (relay contact), measuring stream signal (binary, relay contact), re-measurement signal (relay contact), liquid leakage signal (relay contact), alarm buzzer signal, alarm light signal |
|||||
| Power supply | 100 to 120 V AC, 50/60 Hz | |||||
| Weight | Approx. 150to 180kg depen on specifications |