| Ethernet port: |
For communication with the PC. Automatic recognition of 100Base-TX or 10Base-T
|
| CF (CompactFlash) Card Slot: |

With the CF Card, measured data is saved to the card if communication with the PC is interrupted. Since the card provides data backup, you do not have to worry about the possible loss of data even if the MX is configured for PC-based measurement. |
|
Data Backup Time by CF Card Size
(Note: Minutes/hours/days are approximate.)
Number of
saved channels |
Measurement
interval |
32 M |
128 M |
512 M |
| 10 channels |
10 ms |
2 hours |
9 hours |
36 hours |
| 100 ms |
21 hours |
3.5 days |
15 days |
| 500 ms |
4.5 days |
18.5 days |
75.5 days |
| 2 s |
18 days |
75.5 days |
303 days |
| 24 channels |
10 ms |
54 minutes |
3.5 hours |
15 hours |
| 100 ms |
9 hours |
37 hours |
6 days |
| 500 ms |
45 hours |
7.5 days |
31.5 days |
| 2 s |
7.5 days |
31.5 days |
126 days |
| 60 channels |
10 ms |
18 minutes |
75 minutes |
5 hours |
| 100 ms |
3.5 hours |
15 hours |
2.5 days |
| 500 ms |
18 hours |
3 days |
12.5 days |
| 2 s |
3 days |
12.5 days |
50 days |
|