AXF Remote Flowtube |
AXF Integral Flowmeter |
AXFA14 Converter |
AXFA11 Converter |
| Nominal Pipe Size |
2.5 to 2600 mm
(0.1 to 104 in.)
[depends on model type and process connection type] |
2.5 to 400 mm
(0.1 to 16 in.)
[depends on model type and process connection type] |
For Flowtube
size ; 2.5 to 400mm
(0.1 to 16 in.) |
For Flowtube
size ; 2.5 to 2600mm
(0.1 to 104 in.) |
| Type of use |
General-purpose use,
Ex-proof type,
Sanitary type,
Submersible type |
General-purpose use,
Ex-proof type,
Sanitary type |
General-purpose use,
Ex-proof type |
General-purpose use |
| Fluid Temp. |
-40~160 deg.C (-40 to 320 deg.F)
(-10 to 160 deg.C (14 to 320 deg.F) for Sanitary type) |
- 40~130 deg.C (-40 to 266 deg.F)
(-10 to 130 deg.C (14 to 266 deg.F) for Sanitary type) |
- |
- |
| Ambient Temp. |
-40 to 60 deg.C (-40 to 140 deg.F) [ depends on model type ] |
| Accuracy |
0.35% of rate (Optional ; 0.2% of rate) |
| Fluid Conductivity |
1 micro-S/cm or larger (depends on nominal pipe size and fluid condition) |
| Lining |
Fluorocarbon PFA/Ceramics/Polyurethance Rubber/
EPDM Rubber/ Natural Soft Rubber
[depends on model type] |
- |
- |
| Process Connection |
Wafer, Flange, Sanitary connections
(Clamp[Tri-clamp, DIN, ISO], Union thread[DIN, ISO SMS], Butt-weld), etc. |
- |
- |
| Maximum Cable Length |
- |
- |
100m
(330 ft) |
200m
(660 ft) |
| Indicator |
- |
Multi line backlit LCD (Full dot-matrix) |
| Diagnosis |
Adhesion diagnosis, Empty pipe, Coil open, etc. |
| Alarm message |
Alarm message with corrective measures is indicated (English, German, French, Italian, Spanish, Japanese) |
| Excitation method |
Dual frequency excitation: size 2.5 to 400mm,
Pulsed DC excitation: size 500 to 2600 mm,
Enhanced dual frequency excitation (optional): size 25 to 200 mm |
| Ex-proof type |
ATEX, FM, CSA, IECEx, TIIS |
- |
| Options |
Replaceable electrode, Rotatable terminal box(converter), Mirror finished lining surface(for PFA/Ceramics), Special gaskets, etc. |