Standard |
Multi-Variable |
| Model & code |
DY Vortex Flowmeter
DYA Vortex Flowmeter-remote type converter |
Optional code:/MV |
| Measures |
Liquid, gas, steam (avoid multiphase flow and sticky fluids) |
| Accuracy |
| Liquid: |
| |
±0.75% of reading |
| Gas and steam: |
| |
±1.0% of reading
(velocity 35m/s or less)
±1.5% of reading
(velocity 35m/s to 80m/s) |
|
| Mass flow rate: ±2.0% of reading |
| Fluid temperature: |
| |
Saturated steam or liquid: ±0.5 deg C |
| |
Superheated steam or gas: ±1 deg C |
|
| Repeatability |
±0.2% of reading |
| Output signals |
| Analog: |
| |
4 to 20 mA DC, 2-wire system |
| Transistor contact output: |
| |
Open collector, 3-wire system |
| Pulse, alarm, status output selected by parameter setting Contact rating: |
| |
30 V DC, 120 mA DC |
| Pulse frequency: |
| |
max.10kHz |
| Duty cycles: |
| |
approx.50% (1:2 to 2:1) |
|
| Analog output: |
| |
Selected from flow rate and temperature outputs |
| Transistor contact output: |
| |
When selecting pulse: Flow rate output
When selecting alarm: Temperature sensor failure output
When selecting status: Flow switch signal |
| |
|
| Supply voltage |
10.5 to 42 V DC
16.4 to 42 V DC for digital communications BRAIN and HART protocols
(16.4 to 30 V DC for intrinsically safe type) |
| Process temperature |
-29 to 260 deg C (general)
-196 to 100 deg C (cryogenic version: option)
-29 to 450 deg C (high process temperature version: option) |
| Process pressure |
-0.1 MPa (-1kgf/cm 2) to flange rating |
| Ambient temperature |
-29 to 85 deg C (Integral type / No indicator)
-29 to 80 deg C (Integral type / with indicator) -29 to 85 deg C (Remote type detector) -40 to 85 deg C (Remote type converter / No indicator) -30 to 80 deg C (Remote type converter / with indicator) |
| Ambient humidity |
5 to 100 RH (at 40 deg C) (no condensation) |
| Normal diameter |
15 to 300 mm |
25 to 200 mm |
| Process connection |
JIS10, 20, 40k, ANSI Class 150, 300, 600, 900
DIN PN 10, 16, 25, 40, 64, 100 |
| Electrical connection |
JIS G1/2 female, ANSI 1/2 female, ISO M20 x 1.5 female |
Electrical classification
(now preparing) |
JIS flameproof, FM explosion proof/intrinsically safe
ATEX (CENELEC flameproof/intrinsically safe/IEC type n)
CSA explosion proof/intrinsically safe
SAA flame proof/intrinsically safe |
| Materials (general) |
| Body: SCS14A/CF8M casting stainless steel |
| Shedder bar: duplex stainless steel |
| Gasket: JIS SUS316 stainless steel with polytetrafluoroethylene (Teflon) coating |
| Converter housing and case, cover: aluminum alloy |
|
| Coating color |
Converter case, cover: deep sea moss green (polyurethane corrosion-resistant coating) |
| Functions |
| *Spectral Signal Processing |
| *Self-diagnostics |
| *Analog and pulse simultaneously output |
| *Instrumental error correction |
| *Reynolds number correction |
| *High temperature & cryogenic type |
|
*Temperature monitoring Mass Flowrate output |