Skip navigation
Go to Global Navigation
Go to Primary Contents
Go to Site Information

YOKOGAWA

Yokogawa Electric Corporation

High Process Temperature Version / Cryogenic Version

digitalYEWFLO Vortex Flowmeters

For high temperature or cryogenic flow measurement.

Product Information

digitalYEWFLO Vortex Flowmeters High/Cryogenic Version

digitalYEWFLO Vortex Flowmeter High Process Temperature Version / Cryogenic Version logo
We have the process temperature version and cryogenic version in the digitalYEWFLO series which boast the long-term reliability.
The high process temperature version is available up to 450 degrees C, the highest temperature in the vortex flowmeter.
The cryogenic version is available up to -196 degrees C .
These versions are the best solutions for the high temperature steam application or the cryogenic liquid oxygen up to 200 mm of the nominal sizes.
 
 
  digitalYEWFLO Series catalog
 
  DY and DYA Vortex Flowmeter General Specifications
 
  List of digitalYEWFLO Vortex Flowmeters general specifications
 
  List of digitalYEWFLO Vortex Flowmeters drawings
 

Features: High Process Temperature Version / Cryogenic Version

New functions with Spectral Signal Processing (SSP) technology
  SSP analyses the fluid conditions inside the digitalYEWFLO vortex flowmeter and uses the data to automatically select the optimum adjustment for the application, providing features never seen before in a vortex flowmeter.
SSP accurately senses vortices in the low flow range, providing outstanding flow stability.
 
Advanced self-diagnostics
  Application conditions such as high pipeline vibration and abnormal flow are predicted and indicated.
 
High accuracy
  ±0.75% of reading (liquid)
±1.0% of reading (gas, steam)
 
Wide process temperature range
  High temperature version up to 450 deg C
Cryogenic version minimum -196 deg C
 
Simple parameter settings
  Frequently-used selections grouped together in a quick-access format decrease commissioning time
 
Clear, concise indicator
  Convenient display of the simultaneous and total flow rates together with the process diagnosis
 
Dual output for analog/pulse
  Simultaneous output for flow rate and pulse
 
Alarm output
  An alarm signal is output when an alarm occurs.
 
BRAIN/HART communication and key switches for human-machine interface
 
NACE compliant
 
NAMUR 43 compliant
 
Remote cable length up to 30m

Specifications:High Process Temp. Version / Cryogenic Version

  Standard Multi-Variable Reduced Bore
Model & code DY Vortex Flowmeter Optional code:/MV Option code:/R1,
/R2 (Release in the end
of September)
Fluid to be measured Liquid, gas, steam (avoid multiphase flow and sticky fluids)
Nominal size 15mm ∼ 300mm
(400mm:special)
25mm ∼ 200mm 25mm ∼ 200mm
Accuracy Liquid: ±1.0% of reading(20000≤Re≤1000)
Liquid: ±0.75% of reading(D×1000≤Re)
Liquid: ±1.0% of reading
(20000≤Re≤1000)
Gas, steam: ±1.0% of reading (flow velocity less than 35m/s)
Gas, steam: ±1.5% of reading (flow velocity 35m/s~80m/s)
Output signal Simultaneous output(both analog and transistor contact output available)
Process
temperature
range
-29 deg C ∼ 260 deg C(standard)
-196 deg C ∼ 100 deg C(option: cryogenic version)
-29 deg C ∼ 450 deg C(option: high process temperature version)
Process
pressure
limit
-0.1MPa (-1kg/cm2) to flange rating
Ambient temperature -29 to 85 deg C (Integral type / No indicator)
-29 to 80 deg C (Integral type / with indicator)
-29 to 85 deg C (Remote type detector)
-40 to 85 deg C (Remote type converter / No indicator)
-30 to 80 deg C (Remote type converter / with indicator)
Ambient
humidity
5~100%RH( Non-condensing)
Mounting Integral type and Remote type detector: Flange mounting or wafer mounting Remote type converter: 2 inch pipe mounting
JIS10/20/40、ANSI150/300/600/900, JPI150/300/600,DIN PN10/16/25/40
Electrical connection JIS G1/2 female, ANSI 1/2NPT female, ISO M20×1.5 female
Electrical classification JIS flameproof, FM explosion proof/intrinsically safe
ATEX (CENELEC flameproof/intrinsically safe/IEC type n)
CSA explosion proof/intrinsically safe : Dual Seal
SAA flame proof/intrinsically safe
Material Body: SCS14A cast stainless steel (equivalent to SUS316,CF8M)
Shedder bar: duplex stainless steel (option:anti-corrosion version)
Gasket: SUS316 stainless steel with polytetrafluoroethylene (Teflon) coating
Converter housing and case cover: aluminum alloy
Applicable Standard *EMC Conformity Standards:
  EN61326-1 Class A, Table 2 (For use in industrial locations), EN61326-2-3
  EN55011 Class A Group 1
*Pressure Equipment Directive:
  Notified Body Identification Number 0038 Module H