Skip navigation
Go to Global Navigation
Go to Primary Contents
Go to Site Information

YOKOGAWA

Yokogawa Electric Corporation

FieldMate Versatile Device Management Wizard System Requirements

System Requirements

Hardware Requirements

(1)Software Operating Environment
   
OS ・ Windows 7 Professional 32bit/64bit (English)
・ Windows 7 Home premium 32bit/64bit (English)
・ Windows Vista business 32bit SP2 or later

(2)Hardware Operating Environment
  Windows 7 Windows Vista
PC IBM PC/AT Compatible
CPU Intel® Core™ i5-2520M or similar specification CPU
Main Memory 2GB or more 1GB or more
(2GB or more recommended)
Hard Disk Drive 8GB or more
DVD-ROM Drive Windows 7 compatible Windows Vista compatible
Display 1024×768 or better resolution
recommended
Windows 7 compatible
1024 × 768 or better resolution
recommended
Windows Vista compatible

(3)Network port
  Windows 7 Windows Vista
BRAIN
HART
Interface One USB port USB2.0 standard
Modem USB FieldMate Modem: BRAIN/HART (Yokogawa Option)
USB HART Modem (Yokogawa Option)
FOUNDATION
fieldbus H1
*1
Interface One PCMCIA card slot
Interface board PCMCIA-FBUS Series 2 (National Instruments)
Driver NI-FBUS Communication Manager 4.0.1 or later
FOUNDATION
fieldbus H1
*1
Interface One USB port USB2.0 standard
Interface hardware FFusb (Softing) V1.31 or later*2
PROFIBUS Interface One USB port USB2.0 standard
Interface card & COMM DTM PROFIusb and PROFIdtm (Softing)
PROFIdtm DPV1 V5.45 or later
DP/PA coupler KFD2-BR-A.PA.93 (Pepperl+Fuchs)
6ES7 157-0AC80-0XA (SIEMENS)
HART Interface Bluetooth 2.0
Modem VIATOR ® Bluetooth ® Interface: Model 010041 (MACTek®) *3
ISA100.11a
*4
Interface One USB port USB2.0 standard
Modem Infrared Adapter: ACT-IR224UN-LN96-LE 9600bps (ACTiSYS) *5
Driver Version 1.2.10 or later
ISA100.11a
*6
Interface One Ethernet port

(4)Login
   
Account Administrator privilege

*1: Interface is selectable.
*2: The package is provided complete with FieldMate driver from Softing.
*3: Microsoft supplied Bluetooth stack is used.
*4: ISA100.11a OOB infrared communication
*5: Holder for Infrared Adapter is available (recommended): Gorillamobile Original: GM1 (JOBY, Inc).
*6: ISA100.11a communication via gateway (YFGW710/YFGW410)
 

Combination of FieldMate and Device Files

The following shows the compatibility of revision between FieldMate and Device Files, each DTM.
Yokogawa certifies the combinations below.

FieldMate
*1
Device
Files *2
DTM *3 Comm
DTM
Foundation
Fieldbus
HART ISA100 PROFIBUS BRAIN
R1.02.00 - 2006-1 2006-3 - - - -
R1.02.10 - 2007-1
2007-2
R1.03.0n R1.01.00 2008-1 2008-1 R1.01
- 2008-2 2008-2
R2.01.00 R2.01.00 2008-3 2008-3
R2.01.10 R2.01.10 2009-1 2009-1
R2.01.20 2009-3 2009-2 2009-2
R2.02.00 R3.01.00 2010-1 2010-1 R1.02
ROTAMASS 3 EJX
HART7
R2.03.00 R3.02.00 2011-1 2011-1 YFGW710
Communi-
cation
Device DTM
R3.02.10 2011-2 -
Yokogawa Device DTM Library 1.0
R2.04.00 R3.03.00 2011-4 2011-3 - 2011-2
Yokogawa Device DTM Library 2.0
R2.05.00 R3.04.00 2012-2 2012-3 - 2012-2 ISA100 Communi-
cation
Yokogawa Device DTM Library 3.0
R2.06.00 R3.05.00 2013-1 2013-2 - 2013-2
Yokogawa Device DTM Library 4.0

*1: It shows FieldMate revision.
  FieldMate revision is indicated on the included FieldMate Media label, or starting FieldMate, from main menu, "Help" -> "About FieldMate", current revision can be confirmed.
 
*2: It shows Device Files revision.
  Device Files revision is indicated on the included Device Files Media label.
 
*3: It shows DTM revision.
  From Control Panel of your PC, go to "Add or Remove Program", current revision can be confirmed.
Using the latest DTM, the compatible latest FieldMate is requied. (From R1 to R2, version up is subject to fees.)

Support & Contact Us

  • Download

New Releases

  • Flow | ADMAG AXR
  • Flow | ROTAMASS LR
  • Pressure | DPharp EJA-E

Flow

ADMAG AXR Two-wire Magnetic Flowmeters

ADMAG AXR Two-wire Magnetic FlowmetersEnhanced Version of ADMAG AXR Series Two-wire Magnetic Flowmeters
[Release of explosion-proof models for sizes 150mm and 200mm, SIL2 certification, HART 7 support, Accuracy improvement for explosion-proof models]

Flow

ROTAMASS LR Coriolis Mass Flowmeters

ROTAMASS LR Coriolis Mass FlowmetersThe world's smallest dual bent tube Coriolis Mass Flowmeter

Pressure

DPharp EJA-E Series Differential Pressure and Pressure Transmitter

DPharp EJA-E SeriesThe powerful line-up of DPharp digital family is launched.
Visit our new DPharp Microsite!

Highlights

  • Pressure | DPharp Microsite
  • Flow | ADMAG Microsite
  • Wireless | Field Wireless
  • FieldMate | Asset Management

Pressure

DPharp Microsite

DPharp MicrositeThe highlights of DPharp unique technologies that provides superior performance, stability and reliability in your measurement.

Flow

ADMAG Microsite

ADMAG MicrositeThe highlights of ADMAG series attractive features and specifications that promise you to measure the severe flow stably.

Wireless

The world's first ISA100.11a field wireless products

The world's first ISA100.11a field wireless products- EJX B Series Differential Pressure/Pressure Transmitters
- YTA510 Temperature Transmitter
- YFGW710 Integrated Gateway

Asset Management

FieldMate Versatile Device Management Wizard

FieldMate Versatile Device Management WizardFieldMate is a PC based configuration tool that performs numerous tasks, including initial setup, daily maintenance, troubleshooting, and configuration backup for device replacement.

  • Industry

Language

  • japanese