| Q&A for the basic specifications |
| Q1: |
What is the US300FM? |
| A: |
The US300FM is a fixed-type ultrasonic flowmeter that measures liquid flow volume in a pipe. |
|
| Q2: |
What is the measurement principle of the US300FM? |
| A: |
The transit-time method is used. |
|
| Q3: |
What are the advantages of the US300FM? |
| A: |
One advantage is ease of installation: clamp-on transducers are used for installation on the outside of the pipe. Setup is also quick and easy because the transducers have no zero offset. High accuracy is realized (1% of reading). |
|
| Q4: |
What do I need to consider when I order the US300FM? |
| A: |
The ultrasonic flowmeter (the main electronics unit), transducers, and a connection cable are required. Different transducers are available depending on the pipe size and fluid temperature. Please see the list comparing the ultrasonic flowmeter models. |
|
| Q5: |
Are there reference materials for the US300FM? |
| A: |
Catalogs, general specifications and drawings can be downloaded from our website.
|
|
| Q&A about the product |
| Q1: |
How many sets of transducers are needed for two-path measurement? |
| A: |
Two sets of transducers are needed for two-path measurement. A pair of sensor elements, a junction box, and their integrating cables comprise one set. With one set, one-path measurement can be made. |
|
| Q2: |
I hear that two inputs are available for a single US300FM unit. How about output? Are two outputs available? |
| A: |
Two outputs are available depending on the specifications. |
| |
| Q&A: US300 Series (General) | US300PM (Portable type) |
|