Parameter
|
Specification
|
|
Method of detection
|
Mean value
|
|
Display
|
LCD(Digital display:1999 counts)
|
|
Response Time
|
Approx. 1 second
(approx. 2 seconds on resistance renge)
|
|
Range Switching
|
Manual-range
|
|
Data Hold
|
On all range
|
|
Ambient temperature and humidity
|
-10 to 50 deg.C
(no condensation)
|
up to 30 deg.C, 90% RH |
| up to 40 deg.C, 75% RH |
| up to 50 deg.C, 45% RH |
|
Temperature Coefficient
|
-
|
|
Influence of external magnetic field
|
2A or less at 400A/m
|
|
Influence of conductor position
|
±2% or less
|
|
Safety Standard
|
Conforms EN 61010-1, EN61010-2-031, EN61010-2-032
|
|
Circuit Voltage
|
600Vrms or less
|
|
Withstanding Voltage
|
5.55kV AC for one minute
|
|
Power Supply
|
6F22(006P)9V ×1 or 6LR61 ×2
|
|
Battery Life
|
Approx. 200 hours (continuous)
|
|
Consumed Current
|
Approx. 2mA
|
|
Auto power-off
|
Approx. 10 minutes
|
|
Diameter of measurable conductor
|
30mm at maximum
|
|
Dimensions
|
Approx. 93(W) × 210(H) × 40(D)mm
|
|
Weight
|
Approx. 400g
|
|
Accessories
|
User's manual(IM CL130), batteries, carrying case(93032)
|