30031A and 30032A Leakage Clamp-on Testers

![]()
-
Can measure leakage AC currents of 1mA
-
Can measure a broad range of currents from leakage currents,
at a resolution of 0.001A, to load currents up to 60A.
-
Digital display is enlarged by 20% compared to the previous models.
- Filter function can cut off the harmonics-currents components
from 2nd order (for 30032A only)
Specifications
● AC current measurement
|
Range |
Resolution |
Accuracy |
Max allowable current |
3mA |
0.001mA |
0.010<1<32.70mA: | 3.270mA |
| 30mA |
0.01mA |
1.0% + 5 | 32.70mA |
| 30A |
0.01A |
0.05<1<50.0A: 1.0% + 5 | 32.70A |
60A |
0.1A |
50.0<1<60.6A: 5.0% + 5 | 60.6A |
● AC current measurement (for 30032A only)
|
Range |
Resolution |
Accuracy |
Max allowable current |
3mA |
0.001mA |
0.010<1<32.70mA: | 3.270mA |
| 30mA |
0.01mA |
1.5% + 5 | 32.70mA |
| 30A |
0.01A |
0.05<1<50.0A: 1.5% + 5 | 32.70A |
60A |
0.1A |
50.0<1<60.6A: 5.5% + 5 | 60.6A |
● Zero correction:
3mA range: displays 0.000mA(zero) when 0.010mA <1
30A range: displays 0.00A(zero) when 0.05A <1
● Filter specificatons (for 30032A only)
Amplitude ratio at 100Hz: -38 dB (1.26%) or less (typical: -41 dB)
Amplitude ratio at 120Hz: -53 dB (0.22%) or less (typical: -56 dB)
General Specifications
|
Parameter |
Specification |
|
| Method of detection | Mean value detection and rms-value calibration | |
| Display | LCD | Digital display: 3200 counts |
| Bar-graph display: 32 segments | ||
| Range Switching | Range selection Auto or Manual |
|
| Data hold | On all ranges |
|
| Operating temperature and humidity | 0 to 50 deg.C, 80% RH or less (no condensation) | |
| Temperature Coefficient |
Following values must be added in the temperature range of either 0 to 18℃ or 28 to 50℃. 0<1<50.0A: ±(0.08% of reading /℃ + 0.5 digits/℃) 50.0<1<60.6A:±(0.3% of reading/℃ + 0.5 digits/℃) |
|
| Effect of external magnetic field | 0.0005% typical value (in terms of magnitude of current in adjacent wires) | |
| Safety Standard | Conforms to EN 61010-1, EN 61010-2-032 CAT.III 300V Circuit voltage: 300 V rms or less |
|
| Circuit Voltage | 300Vrms or less | |
| Withstanding Voltage | 3.7kV AC for one minute | |
| Power Supply | One CR2032 (Coin-shaped) 3 V battery | |
| Power consumption | 6 mW max | |
| Battery Life | Approx. 90 hours | |
| Automatic power-off | power approx. 10 minutes after the last switch operation | |
| Diameter of measurable conductor | 40 mm at maximum | |
| Dimensions | Approx. 70(W) × 179(H) × 25(D) excluding protrusions | |
| Weight | Approx. 200g | |
| Accessories | User's manual, battery, soft carrying case (RB057) |
|
Catalog (PDF: 587KB)
User's Manual (30031A) (PDF: 1.06MB)
User's Manual (30032A) (PDF: 1.13MB)