Parameter
|
Specification
|
| Method of detection |
Mean value |
| Display |
LCD(Digital display:1999 counts) |
| Response Time |
Approx. 2 seconds |
| Range Switching |
Manual-range |
| Data Hold |
On all range |
| Ambient temperature and humidity |
0 to 40 deg.C, 85% RH or less (no condensation) |
| Temperature Coefficient |
-
|
| Influence of external magnetic field |
10mA or less in proximity to a 14.4mm-dia
conductor carrying 100A |
| Influence of conductor position |
Within 5dgt for 0 to 50A, or 2% for 50 to 200A
(10mm-dia conductor at inside the jaw) |
| Influence of residual current |
10mA or less in proximity to a 10mm-dia
conductor carrying 50A |
| Safety Standard |
Conforms EN 61010-1, EN61010-2-032 |
| Circuit Voltage |
300Vrms or less |
| Withstanding Voltage |
3.7kV AC for one minute |
| Power Supply |
LR-44 ×2(3V) or SR-44 ×2 |
| Battery Life |
Approx. 15 hours (continuous) |
| Consumed Current |
Approx. 5mA |
| Auto power-off |
Approx. 10 minutes |
| Diameter of measurable conductor |
24mm at maximum |
| Dimensions |
Approx. 60(W) × 149(H) × 26(D)mm |
| Weight |
Approx. 120g |
| Accessories |
User's manual(IM CL320), batteries,
carrying case(93033) |