Skip navigation
Go to Global Navigation
Go to Primary Contents
Go to Site Information

YOKOGAWA

Yokogawa Electric Corporation

TY700Series Digital Multimeter

TY700Series

TY710                   TY720

CE

● Highest Precision

  • Basic accuracy 0.020%
  • True RMS measurement

    ● New Functions for Electronic and Industrial Use
  • Simultaneous measurement and display of DC
        and AC
  • Switchable RMS/MEAN detection※
  • Low-pass Filter (LPF)※
  • AC50mV range※
  • Lo-Power resistance measurement※
       ※TY720 only

    ● Full Support for Data Management
  • A large-capacity logging-mode memory
       TY720: 10,000 data
       TY710: 1,000 data
  • USB communication, application software
       (Optional DMM communication package)

    ● Safe Design and Wide Temperature Range for     Harsh Use
  • Conforms to safety standards EN61010-1
       1000V CAT.Ⅲ , 600V CAT.Ⅳ
  • Safety shutters for preventing erroneous     insertion of test leads into current
        measurement terminals
  • Operating temperature range -20 to +55℃
  • Storage temperature range -40 to +70℃

    ● Closed Case Calibration

    ● 3-year Warranty

  • General Specifications

    Measurement Functions : DC voltage, AC voltage, DCV+ACV, DC current, AC current, DCA+ACA, resistance, frequency, temperature, capacitance,
    duty cycle, decibel calculation, continuity check, diode test, low-power resistance (TY720 only)
    For AC voltage/current, RMS/MEAN detection can be switched (TY720 only).
    For AC voltage/current, the low-pass filter can be turned on/off (TY720 only).
    Additional Functions : Data hold/auto hold/peak hold (TY720 only), range hold, maximum/minimum/average values
    resistance, capacitance zero, relative and percentage value calculation, manual-mode memory, logging-mode memory,
    auto power off, backlight (white LED)
    Display : 5-digit LCD: 7-segment
    Digital display: Main display; [50,000] counts
    Sub-display ; [50,000] counts
    Bar graph display: 51-segment
    Polarity indicator: “-” appears automatically when the polarity is negative
    Overrange indicator: “OL”
    Measuring Rate : 6 times/sec (Frequency: 1 time/sec, Capacitance: max. 0.03 times/sec (50mF), Resistance: 4 times/sec)
    Bar graph display: 15 times/sec
    Operating Temp. and Humidity : -20 to 55℃; 80% RH or less (no condensation) 40 to 55C: 70% RH or less
    Storage Temp. and Humidity : -40 to 70℃; 70% RH or less (no condensation)
    Temperature Coefficient : Add the accuracy 0.05/℃ to the basic accuracy at a temperature within -20 to 18℃ and 28 to 55℃.
    Power Supply : Four AA (R6) dry cells
    Battery Life : Approx. 120 hours (for continuous DC voltage measurement with alkaline cells)
    Withstanding Voltage : 6.88kV for 5 seconds (between input terminals and casing)
    Dimensions : Approx. 90(W) x 192(H) x 49(D) mm
    Weight : Approx. 560g (including batteries)
    Compliance with Standards : Safety EN61010-1, EN61010-031, 1000V CATⅢ, 600V CATⅣ, pollution level 2, indoor, 2000m max. above sea level
    EMC: EN61326-1 Class B, EN55011 Class B Group 1

    Basic Accuracy & Ranges

        TY710 TY720  
    DCV : 0.02% + 5, 0.02% + 5 50.000 mV to 1000.0 V
    ACV:RMS : 0.7% + 30, 0.4% + 30, 50.000 mV to 1000.0 V
    ACV:MEAN :
    n/a,
    1.0% + 30, 50.000 mV to 1000.0 V
    DCV+ACV : 1.0% + 10, 0.5% + 10, 5.000 V to 1000 V
    DCA : 0.2% + 2, 0.2% + 2, 500.00 μA to 10.000 A
    ACA:RMS : 1.0% + 10, 0.75% + 20, 500.00 μA to 10.000 A
    ACA:MEAN :
    n/a,
    1.5% + 20, 500.00 μA to 10.000 A
    DCA+ACA : 1.5% + 10, 1.0% + 10, 500.00 μA to 10.000 A
    Continuity Check : Buzzer Sounds at 100 ± 50 Ω or less, Range:500.0 Ω
    Resistance : 0.1% + 2, 0.05% + 2, 500.00 Ω to 50.000 MΩ
    LOW-power Resistance :
    n/a,
    0.2% + 3, 5.000 kΩ to 5.000 M
    Diode Test : 1.0% + 2,
    1.0% + 2, 2.4000 V
    Temp.※ : 1.0% + 1.5 deg.C, 1.0% + 1.5 deg.C, -200 to 1372℃
    Capacitance : 1.0% + 5, 1.0% + 5, 5.000 nF to 50.00 mF
    Frequency : 0.02% + 1, 0.02% + 1, 2.000 Hz to 99.99 kHz
    Duty Cycle : ±1%, ±1%, 10 to 90%
             
        ※Temperature probe:Type K thermocouple sensor ( optional )
             

    Get Adobe Reader®Viewing pdf files requires Adobe Reader