Humidity Measurement in Dyeing and Discharge Processes
| Industry | : Chemical |
| Product | : Zirconia Humidity Analyzer |
Introduction

There are various methods for continuous fabric dyeing as well as dye fixing. When dye is directly applied, steaming (heat treatment) is required. At present the pad-steam method is widely used for continuous dyeing. To ensure stable product quality, the humidity in the steamer is kept at a constant level. The ZR402G/HS Direct In Situ Zirconia High Temperature Humidity Analyzer provides excellent maintainability as it does not require the use of a sampling system, and ensures stable measurement in high temperature environments. It has been well received in the marketplace and is widely used in humidity control applications.
Expected Benefits
| - | Maintains the quality of the discharge process |
| - | Ensures stable, continuous humidity measurement |
| - | Reduces operating costs |
Process Overview

Humidity Measurement in a Steamer
The pad-steam dyeing process uses vat, reactive, acid, disperse, and other types of dyes, and includes padding, drying, fixing,
washing, and re-drying steps. After padding, the fabrics are forwarded to a steamer where the dye is fixed under conditions of constant
temperature and humidity.
Solution Details
Field Data

Measurement System
Process conditions
Measurement system
Utilities
| Measurement point | Steamer side |
| Sample gas component | Steam: 90 to 100%; air: remaining |
| Temperature | 70 to 110°C |
| Pressure | 10 to 30 kPa |
| Dust | None |
Measurement system
| Detector | ZR22G-☐☐☐-S-H-C-R-☐-E-A/SV |
| Converter | ZR402G-☐-E-E-A/HS/☐ |
| Standard gas unit | ZO21S-☐-E*A |
Utilities
| Power supply | rated voltage: 100 to 240 V AC operating voltage range: 85 to 264 V AC rated frequency: 50/60 Hz operating frequency range: 45 to 66 Hz |
| Power consumption | approx. 100 VA (300 VA max.) |
Notes
It is best to install the detector vertically with the probe head
pointing downward, but it can also be installed at any angle
between 0°and 90° (horizontal installation shown right) with
respect to the vertical.