Module List
Hardware List
| Category | Name |
Model
|
Specifications |
|---|---|---|---|
| FA-M3R | All Modules |
-
|
Common Specifications |
| Base | Base Module *1 |
F3BU04-0N
|
Power supply (F3PU10-0N) + 4 slots (CPU+I/O) |
|
F3BU05-0D |
Power supply (F3PU20/30/26/36) + 5 slots (CPU+I/O) | ||
|
F3BU06-0N
|
Power supply (F3PU10-0N) + 6 slots (CPU+I/O) | ||
|
F3BU09-0N
|
Power supply (F3PU20-0N/F3PU26-0N) + 9 slots (CPU+I/O) | ||
|
F3BU13-0N
|
Power supply (F3PU20-0N/F3PU26-0N) + 13 slots (CPU+I/O) | ||
|
F3BU16-0N
|
Power supply (F3PU20-0N/F3PU26-0N) + 16 slots (CPU+I/O) | ||
| Power Supply | Power Supply Module |
F3PU10-0S
|
100 to 240 V AC (for 4 and 6 slots)(M4 screw) |
|
F3PU20-0S
|
100 to 240 V AC (for 9,13 and 16 slots)(M4 screw) | ||
|
F3PU30-0S
|
100 to 240 V AC (for 9,13 and 16 slots)(M4 screw) | ||
|
F3PU16-0N
|
24 V DC (for 4 and 6 slots) | ||
|
F3PU26-0N
|
24 V DC (for 9, 13and 16 slots) | ||
|
F3PU36-0S |
24 V DC rated output 5V DC/6.0 A (for 9, 13and 16 slots)(M4 screw) | ||
| CPU | Sequence CPU Module (F3SP**-*S) |
F3SP28-3S
|
Ladder 30K step, basic instruction 0.045 μs or longer, with memory |
|
F3SP38-6S
|
Ladder 120K step, basic instruction 0.045 μs or longer, with memory | ||
|
F3SP53-4S
|
Ladder 56K step, basic instruction 0.0175 μs or longer, with memory | ||
|
F3SP58-6S
|
Ladder 120K step, basic instruction 0.0175 μs or longer, with memory | ||
|
F3SP59-7S |
Ladder 256K step, basic instruction 0.0175 μs or longer, with memory | ||
|
F3SP66-4S |
Ladder 56K step, basic instruction 0.0175 μs or longer, with network functions | ||
|
F3SP67-6S |
Ladder 120K step, basic instruction 0.0175 μs or longer, with network functions | ||
| BASIC CPU Module |
F3BP20-0N
|
BASIC language, 120K bytes | |
|
F3BP30-0N
|
BASIC language, 510K bytes | ||
| FA-M3 Value | Value II (with Power Supply) |
F3SC23-1F
|
Consists of F3SP08-SP, F3BU04-0N and F3WD32-3F. |
|
F3SC23-2F
|
Consists of F3SP08-SP, F3BU04-0N and F3WD64-3F. | ||
|
F3SC23-1A
|
Consists of F3SP08-SP, F3BU04-0N and F3XD16-3F, F3YD14-5A. | ||
|
F3SC23-2P
New! |
Consists of F3SP08-SP, F3BU04-0N and F3WD64-3P. | ||
|
F3SC23-6P
New! |
Consists of F3SP08-SP, F3BU04-0N and F3WD64-4P. | ||
| Spare |
F3SP08-SP
|
Sequence CPU (10K steps) with power supply (M4 screw) | |
| Memory Card Module | Memory Card Module |
F3EM01-0N
|
Media: compact flash, FAT16 compatible |
| Memory | ROM Pack |
RK10-0N
|
Ladder 5K step (for F3SP21) |
|
RK30-0N
|
Ladder 20K step (for F3SP20) | ||
|
RK33-0N
|
Ladder 56K step (for F3SP21/28/38/53/58) | ||
|
RK53-0N
|
Ladder 100K step (for F3SP21,F3BP30) | ||
|
RK73-0N
|
Ladder 120K step (for F3SP28/38/53/58) | ||
|
RK93-0N
|
Ladder 256K step (for F3SP28/38/53/58) | ||
| I/O Module | Input Module |
F3XA08-1N
|
100-120 V AC, 8 points, terminal block |
|
F3XA08-2N
|
200-240 V AC, 8 points, terminal block | ||
|
F3XA16-1N
New! |
100-120 V AC, 16 points, terminal block | ||
|
F3XH04-3N
|
High-speed input with pulse catch function, 24 V DC, 4 points, terminal block | ||
|
F3XC08-0N
|
No-voltage contact input, 8 points, terminal block | ||
|
F3XC08-0C
|
No-voltage contact input, separate common, 8 points, terminal block | ||
|
F3XD08-6F
|
For both DC input sink/source, 12-24 V DC, 8 points, terminal block | ||
|
F3XD16-3F
|
For both DC input sink/source, 24 V DC, 16 points, terminal block | ||
|
F3XD16-4F
|
For both DC input sink/source, 12 V DC, 16 points, terminal block | ||
|
F3XD16-3H
|
DC input sink, 24 V DC, 16 points (high-speed input), terminal block | ||
|
F3XD32-3F
|
For both DC input sink/source, 24 V DC, 32 points, connector*2 | ||
|
F3XD32-4F
|
For both DC input sink/source, 12 V DC, 32 points, connector*2 | ||
|
F3XD32-5F
|
TTL input, 5 V DC, 32 points, connector*2 | ||
|
F3XD64-3F
|
For both DC input sink/source, 24 V DC, 64 points, connector*2 | ||
|
F3XD64-4F
|
For both DC input sink/source, 12 V DC, 64 points (8x8), connector*2 | ||
|
F3XD64-6M
|
For both DC input sink/source, 12-24 V DC, 64 points (8x8), connector*2 | ||
| Output Module |
F3YA08-2N
|
Triac (100/240 V AC), 1 A, 8 points, terminal block | |
|
F3YC08-0C
|
Relay (24 V DC, 100-240 V AC), 2A, individual common, 8 points, terminal block | ||
|
F3YC08-0N
|
Relay (24 V DC, 100-240 V AC), 2 A, 8 points, terminal block | ||
|
F3YC16-0N
|
Relay (24 V DC, 100-240 V AC), 2 A, 16 points, terminal block | ||
|
F3YD04-7N
|
TR output, 24 V DC, 2A, independent common: 4 points, terminal block | ||
|
F3YD08-6A
|
TR output, sink, 12-24 V DC, 1 A, 8 points, terminal block | ||
|
F3YD08-6B
|
TR output, source, 12-24 V DC, 1 A, 8 points, terminal block | ||
| TR output, source, 12-24 V DC, 2 A, 8 points, terminal block | |||
|
F3YD14-5A
|
TR output, sink, 12-24 V DC, 0.5 A, 14 points, terminal block | ||
|
F3YD14-5B
|
TR output, source, 12-24 V DC, 0.5A, 14 points, terminal block | ||
|
F3YD32-1B
|
TR output, source, 12-24 V DC, 0.1A, 32 points, connector*2 | ||
| TR high-speed output, sink, 12-24 V DC, 0.1A, 32 points (with short-circuit protector), connector*2 | |||
|
F3YD32-1T
|
TTL output, 5 V DC, 16 mA, |
||
|
F3YD32-1P
|
TR output, sink, 12/24 VDC, 0.1A, 32 points, with short-circuit protector, connector*2 |
||
|
F3YD32-1R
New! |
TR output, source, 12/24 VDC, 0.1A, 32 points, with short-circuit protector, connector*2 | ||
|
F3YD64-1M
|
TR output, matrix scan, 12/24 V DC, 64 points (8x8), connector*2 | ||
|
F3YD64-1P
|
TR output, sink, 12/24 VDC, 0.1A,64 points, with short-circuit protector, connector*2 |
||
|
F3YD64-1R
New! |
TR output, source, 12/24 VDC, 0.1A,64 points, with short-circuit protector, connector*2 | ||
| I/O Module |
F3WD64-3F
|
Input, TR output, sink, 24 V DC, 32 points each, connector*2 |
|
|
F3WD64-3P
New! |
Input, TR output, sink, 24 V DC, 32 points each (with short-circuit protector), connector*2 |
||
|
F3WD64-4F
|
Input, TR output, sink, 12 V DC, 32 points each, connector*2 |
||
|
F3WD64-4P
New! |
Input, TR output, sink, 12 V DC, 32 points each (with short-circuit protector), connector*2 |
||
| Analog I/O Module |
Analog Input Module |
F3AD04-0V
|
0-5V/1-5 V DC, -10-10 V DC input, 4 points, terminal block |
|
F3AD08-1V
|
0-5V/1-5 V DC, -10-10 V DC input, |
||
|
F3AD08-4V
|
0-20 mA, 4-20 mA input, 8 points, terminal block |
||
| High-resolution Analog Input Module |
F3AD04-0R
|
0-5V/1-5 V DC, -10-10 V DC input, 4 points, terminal block, High-resolution 16-bit ADC |
|
|
F3AD08-1R
|
0-5V/1-5 V DC, -10-10 V DC input, 8 points, terminal block, High-resolution 16-bit ADC |
||
|
F3AD08-4R
|
0-20mA DC, 4-20mA DC input, 8 differential inputs, terminal block, 16-bitADC, |
||
|
F3AD08-5R
|
0-5V/1-5V/-10-10V/0-10V DC input, 8 differential inputs, terminal block, 16-bitADC, |
||
|
F3AD08-6R
|
0-5V/1-5V/-10-10V/0-10V DC,
0-20mA DC, 4-20mA DC input 8 differential inputs, terminal block, 16-bitADC, |
||
| Analog Output Module |
F3DA02-0N
|
-10-10 V DC, 4-20 mA DC output, 2 points, terminal block |
|
|
F3DA04-1N
|
-10-10 V DC, 4-20 mA DC output, 4 points, terminal block |
||
|
F3DA08-5N
|
-10-10 V DC output, 8 points, terminal block | ||
| High-speed Data Acquisition Module |
F3HA08-0N
|
0-5 V DC, -10 - 10 V DC input, 8 points, 24 V DC trigger input, 1 point |
|
| Temperature Module |
Temperature Control and PID Module |
F3CU04-0S
|
Universal input(TC,RTD or DC), 4 loops, 100ms/2CH 200ms/4CH, PID ON/OFF control, terminal block |
|
F3CU04-1S
|
F3CU04-0S with continuous PID output (4-20 mADC), terminal block | ||
| Temperature Monitoring Module |
F3CX04-0N
|
Universal input(TC,RTD or DC), 4 channels |
|
| Communications Module | Personal Computer Link Module |
F3LC11-1F
|
1 RS-232-C Port, Modem interface function, connector |
|
F3LC12-1F
|
2 RS-232-C Port, modem interface function, connector | ||
|
F3LC11-2F
|
RS-422 / RS-485 1 port, 115k bps, terminal block |
||
| UT link module |
F3LC51-2N
|
1 RS-422/RS-485 port temporarily connected to digital instrument/adjuster | |
| DeviceNet interface module |
F3LD01-0N
|
Max. 500K bps, DeviceNet port (x1), master/scanner function, connector | |
| Ethernet Interface Module |
F3LE01-0T
New! |
10M bps, 10BASE-T | |
|
F3LE01-5T
|
10M bps, 10BASE5/10BASE-T | ||
|
F3LE11-0T
|
10/100M bps, 10BASE-T/100BASE-TX Remote maintenance function via e-mail |
||
|
F3LE12-0T |
10/100M bps, 10BASE-T/100BASE-TX Messaging(UDP/IP) |
||
| FL-net (OPCN-2) Interface Module |
F3LX02-1N
|
FL-net (OPCN-2) Ver.2.00 compliant, 254 max. connected nodes, 10M bps, 10Base-5 / 10Base-T |
|
| Asi Master Module |
F3LA01-0N
|
AS-interface V2.1 compliant, 100m max, 167k bps |
|
| PROFIBUS-DP Interface Module |
F3LB01-0N
|
1 PROFIBUS-DP port, 12M bps max. | |
| NX Interface Module |
F3NX01-0N
|
MX interface module | |
| RS-232-C Communications Module |
F3RS22-0N
|
Max. 19200 bps, RS-232-C port x 2 (for F3BP20, F3BP30, F3MP30), connector | |
| RS-422 Communications Module |
F3RS41-0N
|
Max. 19200 bps, RS-422/RS-485 port x 1, (for F3BP20, F3BP30, F3MP30), terminal block | |
| Ladder Communications Module |
F3RZ81-0N
|
Max. 19200 bps, RS-232C port x 1, connector | |
|
F3RZ81-0F
|
Max.115200 bps, RS-232C port x 1, connector | ||
|
F3RZ82-0F
|
Max.115200 bps, RS-232C port x2, connector | ||
|
F3RZ91-0N
|
Max. 19200 bps, RS-422/RS-485 port x 1, terminal block | ||
|
F3RZ91-0F
|
Max.115200 bps, RS-422/RS-485 port x 1, terminal block | ||
| GP-IB Communications Module | GP-IB Communications Module |
F3GB01-0N
|
GP-IB port x 1, connector |
| FA link /Fiber-optic FA-bus Module |
FA Link H Module |
F3LP02-0N
|
Max. 32 stations, max. transmission distance 1km, transmission rate 1.25M bps, terminal block |
| Fiber-optic FA Link H Module |
F3LP12-0N
|
Max. 32 stations, max. transmission distance 10 km, max. distance between stations 1 km, transmission rate 1.25M bps, connector | |
| Fiber-optic FA-bus Module |
F3LR01-0N
|
Max. 7 stations, max. transmission distance 200m, transmission rate 10M bps, connector | |
| Fiber-optic FA-bus Type 2 |
F3LR02-0N
|
Max. 32 stations, max. transmission distance 1.4 km, max. distance between stations 500 m, transmission rate 10M bps, connector | |
| FA-bus Type 2 Module |
F3LR02-1W
|
Max. 7 stations, max. transmission distance 80 km, max. distance between stations 10 m, transmission rate 10M bps, wired | |
| Counter/Positioning Module |
High-speed Counter Module |
F3XP01-0H
|
Up/down counter, phase difference, pulse + direction, addition/subtraction etc, 400k pps (x4 multiplication), 1 channel, 32 bits, connector*2 |
|
F3XP02-0H
|
Up/down counter, phase difference, pulse + direction, addition/subtraction etc, 400k pps (x4 multiplication), 2 channel, 32 bits, connector*2 | ||
| Pulse Input Module |
F3XS04-3N
|
Ring-up counter, 0-20k Hz, 24 V input, 4 channels, 16 bits, terminal block | |
|
F3XS04-4N
|
Ring-up counter, 0-20k Hz, 24 V input, 4 channels, 16 bits, terminal block | ||
| Positioning Module (with Multi-channel Pulse Output) |
F3YP04-0N
|
4 axes, max. 250k pps, PTP, connector*2 | |
|
F3YP08-0N
|
8 axes, max. 250k pps, PTP, connector*2 | ||
|
F3YP14-0N
|
4 axes, max.499.75k pps (for pulse motor) / 3.998Mpps (for servo motor) , PTP, connector*2 | ||
|
F3YP18-0N
|
8 axes, max.499.75k pps (for pulse motor) / 3.998Mpps (for servo motor) , PTP, connector*2 | ||
| Positioning Module (Advanced Model with Positioning Pulse Output) |
F3NC11-0N
|
1 axis, max. 250k pps, PTP and linear interpolation, advanced interpolation, position/speed change during operation, connector*2 | |
|
F3NC12-0N
|
2 axes, max. 250k pps, PTP and linear interpolation, advanced interpolation, position/speed change during operation, connector*2 | ||
| Positioning Module (with Pulse Output) |
F3NC32-0N
|
2 axes, 5Mpps max. PTP and CP (linear, circular, and herical interpolation),direct and pattern operation, 2 counters for input from encoder, connector*2 | |
|
F3NC34-0N
|
4 axes, 5Mpps max. PTP and CP (linear, circular, and herical interpolation),direct and pattern operation, 4 counters for input from encoder, connector*2 | ||
| Positioning Module (with Analog Voltage Output) |
F3NC51-0N
|
1 axis, speed instruction voltage output type, connector*2 | |
|
F3NC52-0N
|
2 axes, speed instruction voltage output type, connector*2 | ||
| Positioning Module (with MECHATROLINK-II interface) |
F3NC96-0N
|
15 axes, with MECHATROLINK-II Interface, connector*2 | |
| YHLS Master Module |
F3LH02-0N
|
12M bps max., 2 YHLS ports | |
|
F3LH01-1N
|
12M bps max., 1 YHLS port | ||
|
F3LH02-1N
|
12M bps max., 2 YHLS ports | ||
| YHLS Slave Unit | YHLS Slave Unit |
TACXD08-3AE
|
DC input (sink type), 24DVC, 8 inputs, e-CON |
|
TACXD16-3AM |
DC input (sink type), 24DVC, 16 inputs, MIL | ||
|
TACYD08-1AE
|
Transistor output (sink type), 24VDC, 0.1mA, 8 outputs, e-CON | ||
|
TACYD16-1AM
|
Transistor output (sink type), 24VDC, 0.1mA, 16 outputs, MIL | ||
|
TACYC04-0NB
|
Relay output, 24VDC/250VAC, 1A, 4 outputs, European | ||
|
TACWD08-3NE
|
Input/output(sink type), 24VDC, 4 inputs/4 outputs, e-CON |
||
|
TACWD16-3NM
|
Input/output(sink type), 24VDC, 8 inputs/8 outputs, MIL |
||
| YHLS Slave TAH Series Unit |
TAHWD32-3PAM
|
16 DC inputs (positive common), 24 V DC, MIL 16 TR outputs (sink-type, with short-circuit protection), 24 V DC 0.1 A, MIL | |
|
TAHWD32-3NBM
|
16 DC inputs (negative common), 24 V DC, MIL 16 TR outputs (source-type, with short-circuit protection), 24 V DC 0.1 A, MIL | ||
|
TAHXD16-3PEM
|
16 DC inputs (positive common), 24 V DC, MIL | ||
|
TAHXD16-3NEM
|
16 DC inputs (negative common), 24 V DC, MIL | ||
|
TAHYD16-3EAM
|
16 TR outputs (sink-type, with short-circuit protection), 24 V DC 0.1 A, MIL | ||
|
TAHYD16-3EBM
|
16 TR outputs (source-type, with short-circuit protection), 24 V DC 0.1 A, MIL |
- *1: The rail mount kit must be purchased separately.
- *2: The connector for external connection and connector cover must be purchased separately.
- (Note) For coating treatment, contact Yokogawa's sales office.
Peripheral Devices
| Category | Name | StyleType name | Specification |
|---|---|---|---|
| Peripheral Devices | CPU port / D-sub 9-pin Conversion Cable | KM10-0C | D-sub 9-pin, female, cable length approx. 0.5 m |
| SIO port adaptor Cable *1 | KM10-0S | SIO port / D-sub 9-pin, female, cable 0.5 m long | |
| Cable for Programming Tool *2 | KM11-2T | NEC PC-9801 series compatible, cable length approx. 3 m | |
| KM13-1S
|
Compatible with USB 1.1 compliant USB port, Power supply voltage:+5 V DC(supplied by USB port) Power consumption: 50mA max.(30 mA average) at 5V, cable length approx. 3 m | ||
| Monitor cable (for F3SP08/2□/3□/5□ | KM21-2ANew! | CPU port / D-sub 25-pin, male, 3 m long | |
| KM21-2BNew! | CPU port / D-sub 9-pin, female, 3 m long | ||
| Cable for Monitor *1 | KM21-2N |
SIO port / D-sub 25-pin, male, 3 m long | |
| KM21-2T |
SIO port / D-sub 9-pin, female, 3 m long | ||
| Cable for Terminal Block | KM55-*** | Cable between module and terminal block, 0.5 m (005) to 3 m (030) in steps of 0.5 m | |
| Cable for Optic-fiber FA bus (for Inside Panel) |
KM60-S06 | For inside panel, cable length approx. 0.6 m | |
| KM60-001 | For inside panel, cable length approx. 1 m | ||
| KM60-003 | For inside panel, cable length approx. 3 m | ||
| Cable for Optic-fiber FA bus (for Indoor) | KM61-*** | For indoor, cable length * | |
| KM65-*** | |||
| Cable for optic-fiber FA bus (for Outdoor) | KM62-*** | For outdoor, cable length * | |
| KM67-*** | |||
| YHLS Cable | KM80-*** | Fixed Cable, Cable length *:10m, 50m, 100m, 200m, 300m | |
| KM81-*** | Felexible Cable, Cable length *:10m, 50m, 100m, 200m, 300m | ||
| Terminal Block Unit | TA40-0N | Converts 40 point I/O connector to European type terminal block. | |
| TA50-0N | Connector terminal block (40 points), M3.5 screw | ||
| TA50-1N | Connector terminal block (40 points), M3 screw | ||
| TA60-0N | Connector terminal block (40 points), European type | ||
| Blank Module | F3BL00-0N | For empty I/O slots | |
| Input simulator switch | S9307UF | Simulator switch for input terminals (for F3XD32-□F, F3XD64-□F, F3WD64-□F) |
*: Contact Yokogawa's office.
*1: The cable is to be connected to the connector labelled "SIO" located on the front panel of F3SP66/F3SP67 for higher-level link service (personal computer link functions). It is not to be used for online connection to FA-M3 programming tool WideField2.
*2: These cables for programming tools cannot be used with F3SP66 and F3SP67 CPU modules.
*1: The cable is to be connected to the connector labelled "SIO" located on the front panel of F3SP66/F3SP67 for higher-level link service (personal computer link functions). It is not to be used for online connection to FA-M3 programming tool WideField2.
*2: These cables for programming tools cannot be used with F3SP66 and F3SP67 CPU modules.
Software Packages
| Category | Name | Type name | Category |
|---|---|---|---|
| Development tool |
Ladder diagram support program M3 | SF510-E3W | PC-DOS (IBM-PC/AT compatible), Windows 95,NT4.0, English version |
| BASIC programming tool M3 for Windows | SF560-ECW | Windows 98,Me,NT4.0,2000,XP English version, CD-ROM | |
| FA-M3 programming tool WideField | SF610-ECW | Windows 95, 98, NT4.0 (English version), CD-ROM | |
| FA-M3 programming tool WideField2 | SF620-ECW
|
R4, Windows 2000, XP, VISTA (English version), CD-ROM |
|
| FA-M3 programming tool WideField2 | SF620-MCW |
R5, Windows 2000, XP, VISTA (English or Japanese version), |
|
| FA-M3 ToolBox for Temperature Control and Monitoring Modules | SF661-ECW |
R4, Windows 2000, XP, VISTA (English version), CD-ROM | |
| FA-M3 ToolBox for Positionig Modules | SF662-ECW |
R2, Windows 2000, XP, VISTA (English version), CD-ROM |
Some personal computers and printers cannot be used even if they are of the same series from the same manufacturer, due to CPU type, clock frequency or number of printable digits.
Personal computers with a built-in hard disk are recommended.
For personal computers and printers other than those recommended, contact Yokogawa's sales office to check whether they can be used.
Personal computers with a built-in hard disk are recommended.
For personal computers and printers other than those recommended, contact Yokogawa's sales office to check whether they can be used.