| Item | Specifications | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| F3SP28-3S | F3SP53-4S | F3SP38-6S | F3SP58-6S | F3SP59-7S | F3SP66-4S | F3SP67-6S | |||
| Control method |
Repeating operation (by stored program)
|
||||||||
| I/O computation method |
Refresh method /Direct I/O command
|
||||||||
| Programming language |
Structured ladder language, object ladder language, mnemonic language
|
||||||||
| Number of I/O points |
4096 max.
|
8192 max., including remote I/O points | Max. 4096 | Max. 8192 including remote I/O | |||||
| Number of internal relays (I) |
16384
|
32768
|
65535
|
16384
|
32768
|
||||
| Number of shared relays (E) |
2048
|
||||||||
| Number of extended shared relays (E) |
2048
|
||||||||
| Number of link relays (L) |
8192
|
16384
|
8192
|
16384
|
|||||
| Number of special relays (M) |
9984
|
||||||||
| Number of timers (T) |
2048
|
3072
|
2048
|
3072
|
|||||
| Number of counters (C) |
2048
|
3072
|
2048
|
3072
|
|||||
| Number of data registers (D) |
16384
|
32768
|
65535
|
16384
|
32768
|
||||
| Number of shared registers (R) |
1024
|
||||||||
| Number of extended shared registers (R) |
3072
|
||||||||
| Number of file registers (B) |
32768
|
262144
|
32768
|
262144
|
|||||
| Number of link registers (W) |
8192
|
16384
|
8192
|
16384
|
|||||
| Number of special registers (Z) |
1024
|
||||||||
| Number of labels |
1024
|
||||||||
| Number of input interruption processing routines |
4
|
||||||||
| Constants | Decimal | 16-bit instruction: -32768 to 32767 32-bit instruction: -2147483648 to 2147483647 |
Same as specifications on left, plus:constant definition | ||||||
| Hexadecimal | 16-bit instruction: $0 to $FFFF (hexadecimal number) 32-bit instruction: $0 to $FFFFFFFF (hexadecimal number) |
Same as specifications on left, plus:constant definition | |||||||
| Character-string |
-
|
16-bit instruction: e.g. “AB” 32-bit instruction: e.g. “ABCD” Constant definition (max.255 char) |
|||||||
| Binary |
-
|
Constant definition (max. 256 bytes of continuous data) | |||||||
| IEEE single-precision floating-point |
- |
32-bit instruction: e.g. 1.23, -3.21 Approximately -3.4×1038 to 3.4×1038 (Constant definition allowed) |
|||||||
| Constant index |
-
|
0 to 2047
|
|||||||
| Program capacity (ROM resident allowed) |
30K steps max. | 56K steps max. | 120K steps max. | 254K steps max.360K steps max.(Including tag name definition) | 56K steps max. | 120K steps max. | |||
| Number of program blocks |
1024 max.
|
||||||||
| Number of instructions | Basic |
37 types
|
|||||||
| Application |
324 types
|
389 types | |||||||
| Instruction execution time |
Basic |
0.045 to 0.18μs per instruction
|
0.0175 to 0.07μs per instruction
|
||||||
| Application |
0.18μs per instruction or longer
|
0.07μs per instruction or longer
|
|||||||