Skip navigation
Go to Global Navigation
Go to Primary Contents
Go to Site Information

YOKOGAWA

Yokogawa Electric Corporation

STARDOM FCN/FCJ

New Release R2.20

The cost of sending maintenance engineers to the widely distributed sites to inspect the production equipment poses a heavy financial burden. Yokogawa has enhanced the FCN-RTU low power autonomous controller by adding support for the FOUNDATION fieldbus and HART digital communication protocols, thereby giving it the capability to centrally manage the field devices.With it’s capability, maintenance can be achieved on right time, then maintenance cost is dramatically reduced.

 Go to Press Article

FCN-RTU Enhancement

FCN-RTU support of FOUNDATION fieldbus and HART communication

FCN-RTU supports of FOUNDATION fieldbus provides great benefits for remote applications.

FCN-RTU

  • Reduced wiring cost

FCN-RTU with FOUNDATION fieldbus receives multi-variable data (temperature, pressure, etc.) from a multi-sensing transmitter over a single cable, and also allows multi-drop connections with field devices. This reduces wiring installation and maintenance costs, and the simplified wiring is easier to maintain.

Foundation fieldbus

  • High Accuracy

Communication between FCN-RTU and transmitter via FOUNDATION fieldbus lessens the need for digital-to-analog and analog-to-digital data conversion, and then improves the data accuracy.

  • Highly efficient device inspection and predictive maintenance

By using this FCN-RTU together with Plant Resource Manager (PRM™), Yokogawa’s integrated device management software package, field devices information at remote site can be centrally managed. This information can be used to schedule inspections, improving maintenance efficiency. PRM’s diagnostic functions such as differential pressure transmitter impulse line blocking diagnosis allow maintenance engineers to determine when maintenance should be performed. With predictive maintenance, a device is maintained before it fails; this is particularly useful with devices installed in remote locations, where a quick response is difficult.


Arrow Read more about FOUNDATION fieldbus

Arrow Read more about PRM

FCN-RTU approval of FM Non-incendive

FCN-RTU is compliant with Explosion proof in North America, FM Non-incendive Class I Division 2.

List of Explosion Proof Approved to FCN-RTU

  • FM Non-incendive Class I Division 2
  • CENELECATEX Type "n"
  • CSA Non-incendive Class I Division 2
  • CSA Type "n"

FCN Enhancement

Short base module (Half width of the current base module) is available.


Long Base Module Short Base Module

FCN/FCJ Enhancement

Maximum number of devices using Ethernet communication is increased.

APPF Enhancement

Modbus CommunicationPortfolio

32bit data access POUs (EnronModbus, Dnbus) are prepared.


DNP3 Communication Portfolio

Multi-drop connection is supported.

New POUs setting Event Class are prepared.

Inter-character timeout is supported.


Logging Portfolio

Daily report files over a year are stored on a controller.

Low Power Modules Unveiled

High performance with low power consumption

  • FCNLowPower

Case Studies

Service overview
Update information
Library

Login Members Page

Security Policy

Yokogawa has formulated a basic security policy for its IA products and a concrete security policy and standard for its system products.