New Release R2.20
The cost of sending maintenance engineers to the widely distributed sites to inspect the production equipment poses a heavy financial burden. Yokogawa has enhanced the FCN-RTU low power autonomous controller by adding support for the FOUNDATION fieldbus and HART digital communication protocols, thereby giving it the capability to centrally manage the field devices.With it’s capability, maintenance can be achieved on right time, then maintenance cost is dramatically reduced.
FCN-RTU Enhancement
FCN-RTU support of FOUNDATION fieldbus and HART communication
FCN-RTU supports of FOUNDATION fieldbus provides great benefits for remote applications.

- Reduced wiring cost
FCN-RTU with FOUNDATION fieldbus receives multi-variable data (temperature, pressure, etc.) from a multi-sensing transmitter over a single cable, and also allows multi-drop connections with field devices. This reduces wiring installation and maintenance costs, and the simplified wiring is easier to maintain.

- High Accuracy
Communication between FCN-RTU and transmitter via FOUNDATION fieldbus lessens the need for digital-to-analog and analog-to-digital data conversion, and then improves the data accuracy.
![]()
- Highly efficient device inspection and predictive maintenance
By using this FCN-RTU together with Plant Resource Manager (PRM™), Yokogawa’s integrated device management software package, field devices information at remote site can be centrally managed. This information can be used to schedule inspections, improving maintenance efficiency. PRM’s diagnostic functions such as differential pressure transmitter impulse line blocking diagnosis allow maintenance engineers to determine when maintenance should be performed. With predictive maintenance, a device is maintained before it fails; this is particularly useful with devices installed in remote locations, where a quick response is difficult.
FCN-RTU approval of FM Non-incendive
FCN-RTU is compliant with Explosion proof in North America, FM Non-incendive Class I Division 2.
List of Explosion Proof Approved to FCN-RTU
- FM Non-incendive Class I Division 2
- CENELECATEX Type "n"
- CSA Non-incendive Class I Division 2
- CSA Type "n"
FCN Enhancement
Short base module (Half width of the current base module) is available.
|
|
| Long Base Module | Short Base Module |
FCN/FCJ Enhancement
Maximum number of devices using Ethernet communication is increased.
APPF Enhancement
Modbus CommunicationPortfolio
32bit data access POUs (EnronModbus, Dnbus) are prepared.
DNP3 Communication Portfolio
Multi-drop connection is supported.
New POUs setting Event Class are prepared.
Inter-character timeout is supported.
Logging Portfolio
Daily report files over a year are stored on a controller.