Category Sitemap
Home / Our Businesses / IA / Products / Network-based Control Systems / Product /
VDS
Specifications
VDS Basic Software License
VDS basic software is available in two versions. The full-time version has both development and runtime environments; the runtime version offers only the runtime environment. Use of the runtime version allows a cost-efficient system to be built.

Name Model Description
Basic software license Full-time version NT610FJ Available in 8 types depending on the number of definable tags from 50 to 5000. Includes a license for the first HMI client (Web browser) to access VDS.
Runtime version NT610RJ
Upgrade kit Full-time version NT620FJ Upgrades the basic software license by 1 rank to increase the number of definable tags.
Runtime version NT620RJ
Additional HMI client license NT625AJ License for increasing the number of HMI clients (Web browsers) that can access VDS concurrently.
Optional Software Licenses
The Report Package, Trend Package, Test Package, and Multi-task Package are individually available in two versions: full-time and runtime versions. Use of the runtime version allows a cost-efficient system to be built.
For further details, please send the information requests to us.

Name Model Description
Vista
XP
Report Package Full-time version NT301AJ Helps create monthly, daily, lot, and simple batch reports. (Needs Microsoft Excel to run.)
Y
Y
Runtime version NT301RJ
Trend Package Full-time version NT302AJ Displays trend graphs of data acquired to VDS and saves them as historical data.
Y
Y
Runtime version NT302RJ
Test Package Full-time version NT303AJ Helps debugging by providing I/O simulation functions for debugging without a target machine, device monitor functions to monitor the connected PLCs' statuses, and more.
Y
Y
Runtime version NT303RJ
Multi-task Package Full-time version NT304AJ Enables intercommunication of signals with Visual Basic programs and exchange of array data in a PLC with Visual Basic programs.
Y
Y
Runtime version NT304RJ
Extended Security Package NT320AJ Provides the function of protecting operation file and password management.

Y

Y
Operation Shield Package NT321AJ Improves the operational security such as disabling menu, operation
N
Y
OPC Data Link Package for .NET NT336AJ Enables data exchange between application developed with Visual Studio .NET and OPC server.
Y
Y
Custom Driver NT341AJ Enables a custom driver developed using Microsoft Visual Basic to be installed in VDS.
Y
Y
MELSEC Driver NT351AJ Driver for connecting MELSEC Series controllers from Mitsubishi Electric Corporation.
Y
Y
SYSMAC Driver NT356AJ Driver for connecting SYSMAC Series controllers from OMRON Corporation.
Y
Y
OPC Server Driver NT358AJ Driver for connecting a third-party, OPC DA2.0-compliant server.
Y
Y
DARWIN Driver NT365AJ Driver for connecting Yokogawa DARWIN Series units and DAQSTATION recorders.
Y
Y
Power Monitor Driver NT366AJ Driver for connecting UZ005 and UPM01/02 power monitors from Yokogawa M&C.
N
Y
Data Server and HMI Server
For further details, please send the information requests to us.
Items
Specifications
Personal Computer IBM PC/AT compatible
CPU (*1)
Windows Vista
Pentium III 1 GHz or better
Celeron 1 GHz or better
Windows
XP
Pentium III 700 MHz or better
Celeron 1 GHz or better
RAM
Windows Vista
At least 1 GB
(2 GB or more recommended)
Windows
XP
At least 512 MB
(1 GB or more recommended)
Hard Disk
Windows Vista
At least 2 GB of free space isrequired.
(The overall size of the hard disk of the computer should be 17 GB or more)
Windows
XP
At least 1 GB of free space isrequired.
(The overall size of the hard disk of the computer should be 5 GB or more)
Ethernet adapter An Ethernet adapter that is supported by the operating system specified below isrequired at installation.
CD-ROM Drive A CD-ROM drive that is supported bythe operating system specified below is required (DVD-ROM combo driverecommended).
Peripheral devices An MO, digital audio tape, CD-RW, orother removable storage drive supported by the operating system specified below isrequired for backup.
USB or parallel (Centronics) port Required to install an ID module.
Printer A laser printer or color printer for A4-size paper (that is supported by the operatingsystem specified below) is required. An ESC/P code-enabled serial printer is required for alarm printing.
OS (*6) Windows Vista Business Edition SP1 (*3, *4)
Windows XP Professional SP2
Web browser (*2)
Windows Vista
Internet Explorer 7.0 (*5)
+ Java Plug-in
Windows
XP
Internet Explorer 6.0 SP2
+ Java Plug-in

*1: Some optional software packages may run only under single processing environment. *2: If the same computer runs the HMI server and an HMI client, the system requirements for a data server/HMI server apply.
*3: Some optional software packages may not run on Windows Vista.
*4: Aero style, User Account Control (UAC) and Windows Defender of Windows Vista must be disabled.
*5: Security warning and Phishing Filter of Internet Explorer 7.0 must be disabled. If User Account Control (UAC) of Windows Vista is disabled, Protection mode of Internet Explorer 7.0 will be disabled together.
*6 : Only 32bit version OS is supported.

HMI Client
For further details, please send the information requests to us.
Items
Specifications
 Personal Computer IBM PC/AT compatible
 CPU
Windows Vista
Pentium III 800 MHz or better
Celeron 1 GHz or better
Windows XP
Pentium III 600 MHz or better
Celeron 600 MHz or better
 RAM
Windows Vista
At least 512 MB
(1 GB or more recommended)
Windows XP
At least 256 MB
(512 MB or more recommended)
 Hard disk
Windows Vista
At least 1 GB of free space isrequired. (The overall size of the hard disk of the computer should be 16 GB or more)
Windows XP
At least 10 MB of free space isrequired. (The overall size of the hard disk of the computer should be 1 GB or more)
 Ethernet adapter An Ethernet adapter that is supported by the operating system specified below is required at installation.
 CD-ROM drive A CD-ROM drive that is supported by the operating system specified below is required (DVD-ROM combo drive recommended).
 Peripherals Sound card and speaker are required for audible messages
 OS (*2) Windows Vista Business Edition SP1
Windows XP Home Edition SP2
Windows XP Professional SP2
 Web browser (*1)
Windows Vista
Internet Explorer 7.0
+ Java Plug-in
Windows XP
Internet Explorer 6.0 SP2
+ Java Plug-in
*1: On rare ocasions, graphics on web browser may not be updated.It can be recovered by restarting web browser.
*2: Only 32bit versios OS is supported.
GLOBAL  
YOKOGAWA

Powered by Ultraseek
·  VDS
Login Members Page
Download documents
Security Policy
Yokogawa formulate a Basic Security Policy for IA Products and concrete Security Policy and Standard for System Products.
IA Basic Security Policy
System Security Standard
Microsoft Security Patch Updates Information
Top of this page