| Model |
Product Name |
Input Type |
Output Type |
Descriptions |
| DA1 |
Distributor |
4 to 20 mA DC, from 2-wire type transmitter |
Output 1: 1 to 5 V DC Output 2: DC Voltage or DC Current |
|
DA5
Updated |
Distributor (with Square Root Extractor) |
Field configurable |
| DA9 |
Distributor (Non-isolated) |
Output 1: 1 to 5 V DC |
Non-isolated output |
| DA2 |
Distributor (with Communication Function) |
Output 1: 1 to 5V DC Output 2: 1 to 5 V DC |
BRAIN Communication via DSC/DSC2 card. |
| DA0 |
Output Isolator (Voltage Input/ Current Output Type) |
1 to 5 V DC |
Output 1: DC Current |
1500 V AC (1 min.) of withstand voltage for output signal. |
| DC0 |
Output Isolator (Current I/O Type) |
4 to 20 mA DC |
Output 1: 4 to 20 mA or 10 to 50 mA DC |
| DH0 |
Output Isolator (Voltage I/O Type) |
1 to 5 V DC |
Output 1: DC Voltage |
| DH1 |
Isolator |
DC Voltage or DC Current |
Output 1: 1 to 5V DC Output 2: DC Voltage or DC Current |
Fixed range |
DH2
Updated |
Isolator (Free Range Type) |
Free range Field configurable |
DH5
Updated |
Isolator (with Square Root Extractor) |
1 to 5 V DC |
Field configurable |
DM1
Updated |
Isolator (mV Input Free Range Type) |
DC mV Signal |
Field configurable |
DR5
Updated |
RTD Converter (Free Range Type) |
Resistance Temperature Detector (RTD) |
Output 1: 1 to 5 V DC Output 2: DC Voltage or DC Current |
Field configurable |
| DRU |
Cryogenic Temperature Converter |
Yokogawa J263*B RTD or 4-wire type RTD |
Field configurable |
DT5
Updated |
Thermocouple Converter (Free Range Type) |
Thermocouple |
Field configurable |
DS1
Updated |
Potentiometer Converter (Free Range Type) |
Potentiometer resistance (3-wire type) |
Output 1: 1 to 5 V DC Output 2: DC Voltage or DC Current |
Field configurable |
| DP1 |
Pulse Repeater |
Contact Pulse, Voltage Pulse or Current Pulse |
Output 1: Open collector Output 2: Open collector |
Pulse rate fixed in 1:1 |
| DP3 |
Pulse to Analog Converter |
Output 1: 1 to 5 V DC Output 2: DC Voltage or DC Current |
Field configurable |
| DQ0 |
Analog to Pulse Converter |
1 to 5 V DC or 4 to 20 mA DC |
Output 1: Open collector |
Field configurable |
| DG1 |
PT Converter (R.M.S.) |
AC Voltage from PT |
Output 1: 1 to 5 V DC Output 2: DC Voltage or DC Current |
R.M.S. conversion |
| DB1 |
CT Converter (R.M.S.) |
AC Current from CT |
R.M.S. conversion |
| DD1 |
Tachometer Converter |
AC Voltage from tachometer |
Mean value conversion |
| DF1 |
Pneumatic to Electrical Converter |
Pneumatic Signal |
Output 1: 1 to 5 V DC Output 2: DC Voltage or DC Current |
Input signal range: 0.2 to 1.0 kg/cm2, 3 to 15 psi or 20 to 100 kPa |
| DF0 |
Electrical to Pneumatic Converter |
1 to 5 V DC or 4 to 20 mA DC |
Pneumatic Signal |
| DSK |
Limit Alarm |
DC Voltage or DC Current |
2 Relay Contacts |
2 alarm outputs (N.O. or N.C. configurable) |
| DSC |
Communication I/F Card |
BRAIN Communication |
|
| DSC2 |
Communication I/F Card |
BRAIN/RS485 Communication (Changeable) |
Applicable baud rate: 600 to 9600 bps. |
| DX1 |
Input/Output Thru Card |
Input resistance: 250 ohm (input type 2 only) |
Converts 4 to 20 mA DC signal to 1 to 5 V DC signals |