JUXTA VJ Series Signal Conditioners
Specifications
Common Specifications
| Construction | Compact plug-in type (Main unit with Socket) |
|---|---|
| Mounting Method: | Wall, DIN rail, or dedicated VJ mounting base mountings |
| Connection Method: | M3 screw terminal |
| External Dimension: | Converters: 76×29.5×124.5 mm (H×W×D) |
| VJCE Base: 130×482.6×121 or 177×482.6×121 mm (H×W×D) |
VJ Mounting Base
| Model | Product Name | Descriptions |
|---|---|---|
| VJCE | VJ Mounting Base | The multiple mounting base for VJ Series, mixed and housed up to 16 converters, JIS/EIA standards rack-mounting dimensions. |
Signal Conditioners
| Model | Product Name | Input Type | Output Type | Descriptions |
|---|---|---|---|---|
| VJA1-01 | Distributor | 4 to 20 mA DC, from 2-wire type transmitter |
DC Voltage or DC Current | 1 output type |
| VJA1-02 | 2 outputs type (Note 1) | |||
| VJA4-01 | Distributor (Loop-isolated) |
1 channel type (Note 6) | ||
| VJA4-02 | 2 channels type (Note 6) | |||
| VJA5-01 | Distributor (with Square Root Extractor) |
1 output type | ||
| VJA5-02 | 2 outputs type (Note 1) | |||
| VJA7-01 | Distributor (Multi-function) |
1 output type | ||
| VJA7-02 | 2 outputs type (Note 2) | |||
| VJC1-01 | Loop Powered Isolator | DC Current | DC Voltage or DC Current | 1 output type |
| VJC1-02 | 2 outputs type (Note 1) | |||
| VJH1-01 | Isolator | DC Voltage or DC Current | 1 output type | |
| VJH1-02 | 2 outputs type (Note 1) | |||
| VJH7-01 | Isolator (Multi-function) |
1 output type | ||
| VJH7-02 | 2 outputs type (Note 2) | |||
| VJHF-01 | Isolator (Super Speed Response Type) |
1 output type | ||
| VJHF-02 | 2 outputs type (Note 1) | |||
| VJHR-01 | Isolator (Reverse Output Type) | 1 output type | ||
| VJHR-02 | 2 outputs type (Note 1) | |||
| VJU7-01 | Universal Temperature Converter | Thermocouple, RTD or mV signals | DC Voltage or DC Current | 1 output type |
| VJU7-02 | 2 outputs type (Note 2) | |||
| VJR6-01 | RTD Converter | Resistance Temperature Detector (RTD) |
1 output type | |
| VJR6-02 | 2 outputs type (Note 1) | |||
| VJT6-01 | Thermocouple Converter | Thermocouple | 1 output type | |
| VJT6-02 | 2 outputs type (Note 1) | |||
| VJP1-01 | Pulse Repeater | Contact Pulse, Voltage Pulse or Current Pulse | Open collector or Contactless AC switch | 1 output type |
| VJP1-02 | 2 outputs type (Note 4) | |||
| VJP4-01 | Pulse Rate Converter | 1 output type | ||
| VJP4-02 | 2 outputs type (Note 4) | |||
| VJP8-01 | Pulse Rate Converter (Isolated Single-output and Isolated Dual-output Types) | 1 output type | ||
| VJP8-02 | 2 outputs type (Note 3) | |||
| VJQ8-01 | Pulse to Analog Converter (Multi-function) | DC Voltage or DC Current | 1 output type | |
| VJQ8-02 | 2 outputs type (Note 2) | |||
| VJQ0-01 | Analog to Pulse Converter | DC Voltage or DC Current | Open collector or Contactless AC switch | 1 output type |
| VJQ0-02 | 2 outputs type (Note 4) | |||
| VJQ7-01 | Analog to Pulse Converter (Multi-function) |
1 output type | ||
| VJQ7-02 | 2 outputs type (Note 5) | |||
| VJB1-01 | CT Converter (RMS-computing Type) |
AC Current from CT | DC Voltage or DC Current | 1 output type |
| VJB3-01 | AC Converter (RMS-computing Type) |
AC Current | 1 output type | |
| VJB3-02 | 2 outputs type (Note 1) | |||
| VJG1-01 | PT Converter (RMS-computing Type) |
AC Voltage from PT | 1 output type | |
| VJD1-01 | Tachometer Converter | AC Voltage from tachometer | 1 output type | |
| VJD1-02 | 2 outputs type (Note 1) | |||
| VJF1-01 | Pneumatic to Electrical Converter | Pneumatic signal | DC Voltage or DC Current | 1 output type |
| VJSS-_01 | High / Low Signal Selector | DC Voltage or DC Current | 1 output type | |
| VJSS-_02 | 2 outputs type (Note 1) |
| Note 1: | For the 2nd output, 1 to 5 V DC or 4 to 20 mA DC signal is selectable. |
| Note 2: | For the 2nd output, 1 to 5 V DC, 4 to 20 mA DC, RS-485 Communication or 2 Relay alarm contacts (N.O.) is selectable. |
| Note 3: | For the 2nd output, Open collector, Contactless AC switch or RS-485 Communication is selectable. |
| Note 4: | For the 2nd output, Open collector or Contactless AC switch is selectable. |
| Note 5: | For the 2nd output, Open collector, Contactless AC switch, RS-485 Communication or 2 Relay alarm contacts (N.O.) is selectable. |
| Note 6: | The input/output signal(s) is non-isolated. |