Skip navigation
Go to Global Navigation
Go to Primary Contents
Go to Site Information

YOKOGAWA

Yokogawa Electric Corporation

PC-based Data Acquisition Unit

MX100

Features

Input Modules

NameModelNo. of channelsShortest measurement intervalDescription
30 ch general purpose input module with 500 ms scan speed  MX110-VTDL30 30 500 ms Clamp terminal, DCV/TC/DI
MX110-VTDL30/H3 30 500 ms M3 screw terminal, DCV/TC/DI

Name Model No. of channels Shortest measurement interval Description
Universal Input Modules MX110-UNV-H04 4 10 ms DC voltage, thermocouple, 3-wire RTD, DI (non-voltage contact, Level (5 V logic)). Mixed input allowed.
MX110-UNV-M10 10 100 ms DC voltage, thermocouple, 3-wire RTD, DI (non-voltage contact, Level (5 V logic)). Mixed input allowed.
4-Wire RTD and Resistance Input Module MX110-V4R-M06 6 100 ms DC voltage, 4-wire RTD, 4-wire resistance, DI (non-voltage contact, Level (5 V logic)). Mixed input allowed.
Strain Input Modules MX112-B12-M04 4 100 ms Built-in bridge resistance of 120 ohm
MX112-B35-M04 Built-in bridge resistance of 350 ohm
MX112-NDI-M04 For connection with an external bridge head and strain gauge type sensor (NDIS connector))
5 V Digital Input Module MX115-D05-H10 10 10 ms Non-voltage contact, open collector, and Level (5 V logic). Mixed input allowed.
24 V Digital Input Module MX115-D24-H10 10 10 ms Level (24 V logic), Vth = 12 V

Output Modules

Name Model No. of channels Output update interval Description
Analog Output Module MX120-VAO-M08 8 100 ms Allows mixed voltage (±10 V) and current (4-20 mA) output
PWM Output Module MX120-PWM-M08 8 100 ms Pulse width modulation output module
Digital Output Module MX125-MKC-M10 10 100 ms "A" contact (SPST)

Base Plate

Base plates available for all configurations, from 1 to 6 input/output modules.
When used for the MW100/MX100, you must replace the attachment with the one that comes standard with the MW100/MX100.

Accessories

Connector Covers Connector covers for open slots

AC Adapter (772075) AC adapter for the DC power model.
Operating temperature range: 0 to 40°
*Only for the MW100

Accesories (Removable Terminal)

All input/output terminals are removable except for those of the MX112-NDI-M04. If multiple terminals are prepared ahead of time, no re-wiring is needed between measurements.

Model Description
772061 Screw (M4) terminal block (RJC (reference junction compensation) included). For use in combination with 772062. Compatible with MX110-UNV-M10, MX115-D05-H10, and MX115-D24-H10.
772062 Connection cable between input modules and the screw terminal block. Compatible with MX110-UNV-M10, MX115-D05-H10, and MX115-D24-H10.
772063 Plate with clamp terminals (RJC included). Compatible with MX110-UNV-M10, MX115-D05-H10, and MX115-D24-H10.
772064 Clamp terminals. Compatible with MX110-UNV-H04.
772065 Clamp terminals. Compatible with MX120-VAO-M08, MX120-PWM-M08, and MX125-MKC-M10.
772067 Plate with clamp terminals. Compatible with MX110-V4R-M06.
772068 Plate with clamp terminals (Built-in bridge resistance of 120 ohm). Compatible with MX112-Bxx-M04.
772069 Plate with clamp terminals (Built-in bridge resistance of 350 ohm). Compatible with MX112-Bxx-M04.
772080 Plate with screw (M3) terminal (RJC included).
Compatible with MX110-UNV-M10, MX115-D05-H10, and MX115-D24-H10.
772081 Plate with clamp terminal for current with 10 ohm built in bridge resistance, applies to MX110-UNV-M10
772082 Plate with clamp terminal for current with 100 ohm built in bridge resistance, applies to MX110-UNV-M10
772083 Plate with clamp terminal for current with 250 ohm built in bridge resistance, applies to MX110-UNV-M10

Mounting on Racks or Panels Using the DIN Rail

Use the DIN rail for mounting on on racks or panels. The DIN rail can be easily attached using the dedicated bracket. Two brackets come standard with the base plate (MX150).

Use the DIN rail for mounting on racks or panels. The DIN rail can be easily attached using the dedicated bracket. Two brackets come standard with the base plate (MX150).