| Name |
Model |
Number of channels |
Shortest measurement interval |
Description |
| Universal Input Modules |
MX110-UNV-H04 |
4 |
10 ms |
DC voltage, thermocouple, 3-wire RTD, DI (non-voltage contact, Level (5 V logic)). Mixed input allowed. |
| MX110-UNV-M10 |
10 |
100 ms |
DC voltage, thermocouple, 3-wire RTD, DI (non-voltage contact, Level (5 V logic)). Mixed input allowed. |
| 4-Wire RTD and Resistance Input Module |
MX110-V4R-M06 |
6 |
100 ms |
DC voltage, 4-wire RTD, 4-wire resistance, DI (non-voltage contact, Level (5 V logic)). Mixed input allowed. |
| Strain Input Modules |
MX112-B12-M04 |
4 |
100 ms |
Built-in bridge resistance of 120 ohm |
| MX112-B35-M04 |
Built-in bridge resistance of 350 ohm |
| MX112-NDI-M04 |
For connection with an external bridge head and strain gauge type sensor (NDIS connector)) |
| 5 V Digital Input Module |
MX115-D05-H10 |
10 |
10 ms |
Non-voltage contact, open collector, and Level (5 V logic). Mixed input allowed. |
| 24 V Digital Input Module |
MX115-D24-H10 |
10 |
10 ms |
Level (24 V logic), Vth = 12 V |
|
 |
 |
| Name |
Model |
Number of channels |
Ouput update interval |
Description |
| Analog Output Module |
MX120-VAO-M08 |
8 |
100 ms |
Allows mixed voltage (±10 V) and current (4-20 mA) output |
| PWM Output Module |
MX120-PWM-M08 |
8 |
100 ms |
Pulse width modulation output module |
| Digital Output Module |
MX125-MKC-M10 |
10 |
100 ms |
“A” contact (SPST) |
|
Base plates available for all configurations, from 1 to 6 input/output modules.
When used for the MW100/MX100, you must replace the attachment with the one that comes standard with the MW100/MX100. |
 |
Connector Covers
Connector covers for open slots |
| |
AC Adapter (772075)
AC adapter for the DC power model.
Operating temperature range: 0 to 40°
*Only for the MW100 |
|
|
Accessories (Removable Terminal)
|
 |
All input/output terminals are removable except for those of the MX112-NDI-M04. If multiple terminals are prepared ahead of time, no re-wiring is needed between measurements.
| Model |
Description |
| 772061 |
Screw (M4) terminal block (RJC (reference junction compensation) included).
For use in combination with 772062. Compatible with MX110-UNV-M10, MX115-D05-H10, and MX115-D24-H10. |
| 772062 |
Connection cable between input modules and the screw terminal block.
Compatible with MX110-UNV-M10, MX115-D05-H10, and MX115-D24-H10. |
| 772063 |
Plate with clamp terminals (RJC included).
Compatible with MX110-UNV-M10, MX115-D05-H10, and MX115-D24-H10. |
| 772064 |
Clamp terminals. Compatible with MX110-UNV-H04. |
| 772065 |
Clamp terminals. Compatible with MX120-VAO-M08, MX120-PWM-M08, and MX125-MKC-M10. |
| 772067 |
Plate with clamp terminals. Compatible with MX110-V4R-M06. |
| 772068 |
Plate with clamp terminals (Built-in bridge resistance of 120 ohm). Compatible with MX112-Bxx-M04. |
| 772069 |
Plate with clamp terminals (Built-in bridge resistance of 350 ohm). Compatible with MX112-Bxx-M04. |
| 772080 |
Plate with screw (M3) terminal (RJC included).
Compatible with MX110-UNV-M10, MX115-D05-H10, and MX115-D24-H10. |
| 772081 |
Plate with clamp terminal for current with 10 ohm built in bridge resistance, applies to MX110-UNV-M10 |
| 772082 |
Plate with clamp terminal for current with 100 ohm built in bridge resistance, applies to MX110-UNV-M10 |
| 772083 |
Plate with clamp terminal for current with 250 ohm built in bridge resistance, applies to MX110-UNV-M10 |
|
 |
Use the DIN rail for mounting on on racks or panels. The DIN rail can be easily attached using the dedicated bracket. Two brackets come standard with the base plate (MX150).
|
 |
Use the DIN rail for mounting on racks or panels. The DIN rail can be easily attached using the dedicated bracket. Two brackets come standard with the base plate (MX150). |
|
|
|
|
|
|