Category Sitemap
Home / Our Businesses / Controllers & Data Acquisition / Products / Chart Recorders /
Handy Oscillographic Recorders

OR100E/OR300E
Features
  1 2 3 4  
OR100E OR300E
Basic system 2-channel and 4-channel
standard models
2-channel and 4-channel models
with harmonic analysis
Input types DC, TC or Off DC, TC, RMS or Off
Measurement
modes
Real-Time Recording, Memory,
Real-Time + Memory
Real-Time Recording, Memory, Real-Time
+ Memory, Harmonic Analysis
Input performance 400 kS/s, effective 11 bits A/D, maximum 500V rms input
Memory length 128 K of data per channel
External
dimensions (mm)
Approximately 190 (W) x 46 (H) x 256 (D)
Weight (4-channel
model without battery)
Approximately 1.4 kg Approximately 1.5 kg

The notebook-size OR100E/OR300E
Series weighs only 1.4 kg* but can take simultaneous measurements on up to four isolated analog channels. The analog input unit can directly measure voltages as high as 500 Vrms operating at high speed and high resolution (400 kS/s, 11 bits). The OR100E/OR300E Series supports logic measurements on as many as eight channels using optional logic probes, enabling twelve simultaneous analog and logic measurements at high speed.

* OR100E 4-channel model; not including battery weight

Wave window trigger
Wave window trigger
The wave window trigger enables real-time monitoring of problems that are difficult to pick up with conventional triggers, such as instantaneous power failure, sagging, and impulses on utility power supplies (50 or 60 Hz).
Temperature Measurement
In addition to the direct measurement capability (up to 500 Vrms), the new OR100E/OR300E includes a temperature input adapter (788041-1) that works with type K thermocouples. The adapter is powered by the OR100E/OR300E, so there's no need for a special power supply when you use the recorder in the field or take long-duration measurements. The OR100E/OR300E has a special temperature input adapter range (see the diagram below) for easy setup.

The OR100E/OR300E lets you write measurements continuously and in real time to an ATA flash memory card (PCMCIA card). This means internal memory capacity is no longer a limitation on total recording time*1, allowing you to take long-duration measurements previously handled by data recorders. You can also display measured data stored in flash memory on the OR100E/OR300E display for easy field checks.*2 In addition, ACRAWin32 is available to assist you in making reports when handling massive amounts of data.

*1 : Maximum sampling rate: 1.6 kS/sec;
*2 : Displays 128 kdata/ch steps

Standard data memory time
For 20 MB PC card For 160 MB PC card
Measurement
cycle
Time/div
(Hz)
example
1 s/div (80Hz) 50 msec/div
(1.6 kHz)
1 s/div (80 Hz) 50 msec/div
(1.6 kHz)
Measument
time
4 analog
channels
and 8 logic
channels
Approximately
170 minutes
(2.8 hours)
Approximately
8 minutes
Approximately
1380 minutes
(23 hours)
Approximately
65 minutes
(1 hours)
4 analog
channels
Approximately
515 minutes
(8.5 hours)
Approximately
25 minutes
Approximately
4100 minutes
(68 hours)
Approximately
200 minutes
(3.3 hours)
for field use
In trigger standby mode
In addition to working with a 3.5-hour* rechargeable battery (788021), the OR100E/OR300E also can be powered by an AC adapter (100-240 V), DC adapters (12 V/24 V/48 V), and alkaline batteries. Choose the power supply type that best fits your needs.
GLOBAL  
YOKOGAWA

Powered by Ultraseek
·  OR100E/OR300E
Support
Daqstation DXAdvanced
Top of this page
  1 2 3 4