Cell Voltage Measurement for Fuel Cells, Secondary Batteries and Electrolyzers
The MX100/MW100 is best suited for applications where the voltage of each cell in fuel cells, secondary batteries and electrolyzers is measured. The high withstand voltage performance of the MX100/MW100 makes it possible to safely measure the voltage of each cell.
  • The MX100 is recommended for 60-channel or greater multichannel measurements. With MXLOGGER, multiple units can be measured simultaneously.
  • The universal input module can simultaneously measure not only voltages but also temperatures and contact signals. With the strain module, static strain can also be measured simultaneously.
  • An output module is available as well. This module can be used to output pattern data in durability tests or simplyly automate test equipment.