MW100 Data Acquisition Unit
Questions
Questions and Answers
InternetExplorer
On the Tools menu, click Internet options > Temporary Internet files > Delete files, then select the Delete all offline contents check box and click OK.
If using Java Runtime by Sun Microsystems, also perform the following procedure.

Java Runtime 1.4
On the Windows Start menu click Settings > Control panel, then double-click the Java Plug-in icon to open the Java Plug-in control panel. Next, click the Clear button on the Cache tab, then click Yes in the confirmation dialog box that appears.

Java Runtime 1.5
On the Windows Start menu click Settings > Control panel, then double-click the Java icon to open the Java control panel. Next, click the Delete files button under Temporary Internet files on the Basic tab, then click Yes in the confirmation dialog box that appears.

Caution:
If you clear the Web browser's cache, all cookies and temporary files displayed in the past will be deleted.

* After the cache is cleared, it may take a few seconds to load pages when you visit them for the first time, but on and after the second time they will be displayed as quickly as before.
Top of this page
Refreshing of waveform data sometimes slows down depending on the number of displays in the Web monitor or the network load status. When real-time refreshing of waveforms is required, reduce the number of displays.
Top of this page
Key operation and Web setup operation setting error, or error occurred during recording operation. Referring to the user’s manual, check the details of the error. When an error is displayed, the display can be cleared from Status setting > System setting in the Web setup screen or by pressing the Stop key. You can clear one error that is displayed by pressing the Stop key. (Up to three error codes are saved.)
Top of this page
A possible cause is that measurement is in progress. If so, stop measurement in the Top screen.
Top of this page
A possible cause is that the module is not being detected. Check the module information in the System Setting > Module Information. If the module is not being detected, turn the power OFF and check the module’s installation to reconfigure the system in the System Setting > Module Information.
Top of this page
When a module is changed and system reconfiguration is executed, the settings return to their defaults. Carry out range settings again.
Top of this page
FTP client cannot transfer files to two locations. When file transfer to the primary master equipment fails, then the transfer to the secondary master equipment is performed.
Top of this page
This indicates that FTP client operations are being executed. When that indication continues for a long period, the FTP client settings may be wrong. Check the FTP client settings to make sure that they are correct.
Top of this page
When the pulse input module is installed on the MW100, you can use computations for pulse input module integration. Therefore, the Math option need not be specified for integrations. However, the Math option (/M1) is required if you want to combine other computations besides integration. Also, you can use the report function (/M3) to make records of flow calculations (hourly, daily, weekly, and monthly reports), or power integration bar graphs. Since report data can be saved in text format, you can load it into Excel or other programs to create reports with customized forms.
Top of this page