Introducing Useful Functions
µR Intelligent Industrial Recorders
![]()
Customized Menu (Standard Function with Version 1.31 and Later)
With the µR10000/µR20000 (version 1.31 or later), the customer can change the display menus for operation and settings according to his or her application. This simplifies operation and settings, and prevents mishandling or erroneous settings entry.
The µR10000/µR20000 offers three modes: Operation mode, Setting mode, and Basic Setting mode. The menus displayed in two of these modes, Operation and Setting modes, can be changed.

Selection Range for Displayed Menus
The range of menus that can be shown or hidden in each mode is shown below. Enabling and disabling of each menu's settings and the Customized Menu function is performed in Basic Setting mode.
- Operation mode
The following menus of the FUNC key apply.- Manual print (print out measured values)
- Setup list (print out the contents specified in Basic Setting mode)
- Message (print out message)
- Buffer_clear (clear the alarm print out buffer)
- Periodic (reset the report data for periodic printout)
- Setting mode
The following menus of Setting mode apply.- Range (set input range)
- Bias (apply bias to measured input signal)
- Alarm (set alarms)
- Unit (set units for linearly scaled channels)
- Chart_speed (change chart feed speed)
- Aux (set recording interval, zone recording, partial compression/expansion, and other settings)
- Calibration (correct the input value; with the /CCC1 option)
- Math (enter equations; with the /M1 option)
- Batch_name (set batch and lot number; with the /BT1 option)
- Batch_detail (detailed settings of the batch function; with the /BT1 option)
- μR10000/μR20000 operation when customized menu enabled
- Hides menus set to "hide" in the FUNC key menu.
- Hides menus set to "hide" in Setting mode.
- Locks Basic Setting mode (password set in advance required to unlock).