The Yokogawa Model TA320 provides the following solution for this application :
- Continuous Measurement
The TA320 can continuously measure the period, pulse width and time interval of the signal at a maximum rate of 14 MSPS with a maximum time resolution of 100 pico-seconds. Thus, rare misfires are easily detected.
- Time Stamp Mode
The TA320 has a Time Stamp Mode as its sampling method. In this mode, measurement values and its measurement time are each measured, enabling the variation of the measurement results with time to be analyzed using a time variation display. This is an excellent method of detecting misfire timing.
|