Digital Oscilloscopes

DL1720E/ DL1735E/ DL1740E/ DL1740EL
Features
  1 2 3 4  
Long Memory and Easy Zoom FunctionAll-Points Display and Fast Screen UpdatesSmart Search Function
History Memory and History SearchMeasuring Periodically Fluctuating AmplitudesHow can I quickly count a large number of pulses in a waveform?
Envelope and Roll modesSimple and Enhanced TriggersGO/NO GO Judgment
Dedicated I²C Bus Trigger and Analysis FunctionDedicated SPI Bus Trigger and Analysis FunctionUSB
EthernetOutputting and Viewing Screen ImagesRear Panel
Cycle Statistics
Cycle Statistics
Cycle Statistics
Automatically calculates the maximum value, minimum value, average value, and standard deviation of selected waveform parameters for each period of a signal. You can even find the period corresponding to the calculated maximum and minimum values and display that period in the zoom window. In some applications, like with a PWM (pulse width modulation) control signal, you may need to determine information about each waveform period for long amounts of time. The DL1700E Series with its long memory, lets you analyze a long waveform, period-by-period, based on the period of a reference signal.
Pulse count
Pulse count
Pulse Count
Automatically counts the number of pulses in the waveform data between cursors. The threshold level for recognizing a single pulse is user-definable, so you can reliably compute pulses even in signals with unstable levels. With the DL1700E Series, you'll never again have to manually count pulses on screen or on a stack of printouts.
Envelope and Roll modes for simultaneously observing both slow and fast signals

Envelope mode always captures signals at the highest sampling rate, irrespective of the time-axis setting. This mode is effective when observing high-frequency noise superimposed on a slow signal. Roll mode allows you to observe signals on the screen in much the same way as you record them on a chart recorder. When in normal mode, you can set the sampling rate as high as 2 MS/s for roll mode. In addition, you can have a roll-mode view of signals in the envelope mode.

Roll-mode View in Normal Mode
Roll-mode View in Normal Mode
Roll-mode View in Envelope Mode
Roll-mode View in Envelope Mode

Products Home Specifications Software Testimonials Accessories
Viewing PDF files requires Adobe Reader.
GLOBAL  
YOKOGAWA

Powered by Ultraseek
·  DL1720E/ DL1735E/ DL1740E/ DL1740EL
See Also...
DL Series Selection Guide
Find the right one for you!
more
Serial Bus Analyzer Selection Guide
For I2C, CAN, and SPI analysis
more
Probes for Digital Oscilloscopes
Supporting a variety of measurement
more
Accessories for DL series
Accessories other than probes
more
FAQ
For the DL series
more
  1 2 3 4