Functions
  1 2 3 4  
Generation and Measurement TimingZero Generation Function of Voltage and Current External Input/Output and Synchronized OperationEasy File Operation with the USB Storage Function
User-Defined Computation FunctionEthernet Interface (/C10 Option)Rear panel 
The zero generation function of the GS610 enables the generation of the voltage/current zero value as well as the switching of the output condition between high and low impedance. In the zero generation condition, the voltage application or current supply to the load can be stopped with the output relay turned ON. This function avoids the problems of chattering and contact life of the output relay and reduces the ON/OFF operation time of the output.

Zero generation of voltage
- Low impedance: The current limiter is set to the specified value.
- High impedance: The current limiter is set to 0.5% of the range.
Voltage
Zero generation of current
- Low impedance: The voltage limiter is set to 0.5% of the range.
- High impedance: The voltage limiter is set to the specified value.
Current
The GS610 has various external input/output connectors. Signals such as the trigger input/output indicating the timing of generation and measurement, the output relay ON/OFF control signal, the zero generation ON/OFF control signal, and the comparator judgment result output can be input/output from the BNC and multi-core connectors. In addition, multiple GS610s can be synchronized by simply connecting the trigger output of a GS610 to the trigger input of another GS610 using a BNC cable.
(For the external view of the connector type, see the "Rear Panel" section on page 7.)

Input/Output

Signal Name Function
TRIG IN Trigger input
SWEEP START IN Sweep start input
CTRL IN INTERLOCKInterlock input
OUTPUTRelay control input
ZEROZero generation control input
TRIG OUT ORIGINTrigger output
SOURCE CHANGESource change timing output
MEASURE BEGINMeasure start timing output
MEASURE ENDMeasure end timing output
PULSE ENDPulse falling edge timing output
SWEEP SYNC OUT ORIGINSweep synchronization output
TURN ENDSweep 1 turn end timing output
ALL ENDSweep all end timing output
CTRL OUT INTERLOCKInterlock through output
OUTPUTRelay status output
ZEROZero generation status output
PROGRAMProgrammable output
COMPARE HIComparison result output HIGH
COMPARE INComparison result output IN
COMPARE LOComparison result output LOW
COMPARE OVComparison result output OVERRANGE
COMPARE ENDCompare end