Category Sitemap
Home / Our Businesses / Test & Measurement / Products / Wireless Communication Equipment /
Mobile Phone Tester

VC200
Product Home · Specifications Features Accessories
Specifications
Test Functions
  • Call Processing
  • Frequency Switch
  • Maximum Output Power Measurement
  • Minimum Output Power Measurement
  • Open Loop Power Control
  • Inner Loop Power Control
  • EVM / Frequency Error
  • Reference Sensitivity (BER)
  • Maximum Input (BER)
  • Sound loop back
Transmission Frequency

Band I (2110.0 to 2170.0 MHz)
Band II (1930.0 to 1990.0 MHz)
Band III (1805.0 to 1880.0 MHz)
Band VI (875.0 to 885.0 MHz)

Transmission Power

Range: -110.0 to -10.0 dBm (resolution : 0.1dBm)
Absolute Accuracy: ±1.5dB (> -60dBm), ±2.0dB (< -60dBm)

Reception Frequency

Band I (1920.0 to 1980.0 MHz)
Band II (1850.0 to 1910.0 MHz)
Band III (1710.0 to 1785.0 MHz)
Band VI (830.0 to 840.0 MHz)

Reception Power (Tx Power Measurement)

Maximum input level: +35dBm
Measurement range: -70 to +35dBm
Absolute accuracy: ±1.5dB

Frequency Error Measurement

Range: 0 to ±10 kHz
Residual error: ±0.01ppm


EVM Measurement

Residual EVM: approx. 4%
Test Functions
  • Call Processing
  • Frequency switch
  • Power measurement
  • Phase and Frequency error
  • Rx Quality
  • Rx Level
  • Loop back BER / FER
  • Burst timing
  • Sound loop back
GSM Band

GSM850, P-GSM, E-GSM, R-GSM, DCS1800, PCS1900

Transmission Power

Range: -110.0 to -10.0 dBm (resolution: 0.1dBm)
Absolute accuracy: ±1.5dB (> -60dBm), ±2.0dB (< -60dBm)

Reception Power (Tx Power Measurement)

Maximum input level: +40dBm(GSM Burst), +35dBm(CW)
Range: -40 to +35dBm
Absolute accuracy: ±1.5dB

Phase Error Measurement

Range: peak 0.5 to 45deg, rms 0.5 to 20deg
Residual error: approx. 1.4deg (rms)

Frequency Error Measurement

Range: 0 to ±10kHz
Residual error: ±0.02ppm
Display: Color LCD VGA
Interface: 100BASE-TX, USB, RS-232
Language: English, Japanese, Chinese
Operating ConditionsTemperature: +5 to +35&°C Humidity: 20 to 80%RH
Rated supply voltage: 100 to 120VAC / 200 to 240VAC
Allowable supply voltage: 48 to 63Hz frequency range
Maximum power: 150VA or less consumption
External dimensionsApprox. 283(W) x 176(H) x 303(D) mm
Weight: approx. 6.5kg
GLOBAL  
YOKOGAWA

Powered by Ultraseek
·  VC200