EJA115 Low Flow Transmitter

The model EJA115 Low Flow Transmitter is a flowmeter that has an integral orifice. It is ideal for very low flow measurement.

Product Information

EJA115 Low Flow Transmitter

BRAIN HART FF PROFIBUS CE Ctick Logo

DPharp logo
The model EJA115 Low Flow Transmitter is a differential pressure transmitter assembled with an integral orifice and excellent for very low flow measurement. It outputs a 4 to 20 mA DC signal corresponding to the measured flow.

The orifice is available in six types with a bore ranging from 0.508 mm to 6.350 mm. The combination of the bore selection with the differential pressure measurement span variation of the differential pressure transmitter enables a wide range of very small flow measurement.
 
The EJA Series is available with BRAIN, HART, FOUNDATION™ fieldbus or PROFIBUS PA communication protocols.
 
 
  EJA115 general specifications PDF
 
  EJA115 User's Manual PDF
Terms of Use for Manuals
 
  List of EJA series low flow transmitter general specifications
 
  List of EJA series low flow transmitter drawings
 

Features

Excellent performance and stability
  The EJA series uses a silicon resonant sensor formed from monocrystal silicon, a perfect material which has no hysteresis in pressure or temperature changes. The sensor minimizes overpressure, temperature change, and static pressure effects, and thus offers unmatched long-term stability.
 
Compact and light-weight design
  Half the weight of conventional models thanks to miniaturization of the casing with the amplifier ASIC, pressure cell structure, and flange. The ASIC uses the minimum number of parts and improves the reliability of the amplifier.
 
Fieldbus communication capability
  Fieldbus is a digital two-way communication system. It is a revolutionary technology for configuring instrumentation control systems and a promising successor to the standard 4 to 20 mA analog communication used in most field instruments today.
EJA series offers two types of fieldbus models, FOUNDATION™ fieldbus Low Voltage Mode and PROFIBUS PA devices, which ensure interoperability between Yokogawa and other manufactures. As for software, the EJA series incorporates two AI function blocks that compute differential and static pressures to allow flexible configuration of instrumentation.

Specifications

  EJA115 Low Flow Transmitter
L Capsule M Capsule H Capsule
Water equivalent 0.016 to 7.2 l/min 0.022 to 23 l/min 0.07 to 33 l/min
Air equivalent flow 0.44 to 198 Nl/min 0.63 to 635 Nl/min 2 to 910 Nl/min
Differential pressure span 1 to 10 kPa
(2 to 40 inH2O)
2 to 100 kPa
(8 to 400 inH2O)
20 to 210 kPa
(80 to 840 inH2O)
Accuracy ±5% ±5% ±5%
Degrees of protection IP67, NEMA 4X, and JIS C0920 immersion proof
Certificates FM, CENELEC ATEX, CSA, TIIS, IECEx
Output 4 to 20 mA DC or FOUNDATION™ fieldbus or PROFIBUS PA 2-wire system with digital communication
Supply voltage BRAIN and HART:10.5 to 42 V DC (10.5 to 30 V DC for Intrinsically safe type)
Fieldbus:9 to 32 V DC (9 to 24 V DC for Entity model and 9 to 17.5 V DC for FISCO model)
Ambient temperature -40 to 85 deg C (-40 to 185 deg F) (general use type)
-30 to 80 deg C (-22 to 176 deg F) (with integral indicator)
Process temperature -40 to 120 deg C (-40 to 248 deg F) (general use type)
Maximum working pressure 3.5 MPa
(500 psi)
14 MPa
(2000 psi)
Mounting 2-inch pipe mounting
Wetted parts material Capsule SUS316L(Diaphragm material is Hastelloy C-276)
Manifold SUS316
Cover flange SUS316
Housing Cast aluminum alloy or SUS316 equivalent stainless steel (optional)