EJA438 Diaphragm Sealed Gauge Pressure Transmitters

Models EJA438W, EJA438N Diaphragm Sealed Gauge Pressure Transmitters can be used to measure liquid, gas, or steam flow as well as liquid level, density, and pressure.

Product Information

EJA438 Diaphragm Sealed Gauge Pressure Transmitters

BRAIN HART FF PROFIBUS CE Ctick Logo

DPharp logo
Diaphragm seal is used to prevent process medium from entering directly into the pressure-sensing assembly of the pressure transmitter. It is connected to the transmitter using capillary filled with fill fluid.

Models EJA438W and EJA438N Diaphragm Sealed Gauge Pressure Transmitters can be used to measure liquid, gas or steam pressure. They output a 4 to 20 mA DC signal corresponding to the measured pressure.
 
The EJA Series is available with BRAIN, HART, FOUNDATION™ fieldbus or PROFIBUS PA communication protocols.
 
 
  EJA438W and EJA438N general specifications
PDF
 
  EJA438W and EJA438N User's Manual PDF Terms of Use for Manuals
 
  List of EJA series pressure transmitter general specifications
 
  List of EJA series pressure transmitter drawings
 

Features

Excellent performance and stability
  The EJA series uses a silicon resonant sensor formed from monocrystal silicon, a perfect material which has no hysteresis in pressure or temperature changes. The sensor minimizes overpressure, temperature change, and static pressure effects, and thus offers unmatched long-term stability.
 
Compact and light-weight design
  Half the weight of conventional models thanks to miniaturization of the casing with the amplifier ASIC, pressure cell structure, and flange. The ASIC uses the minimum number of parts and improves the reliability of the amplifier.
 
Fieldbus communication capability
  Fieldbus is a digital two-way communication system. It is a revolutionary technology for configuring instrumentation control systems and a promising successor to the standard 4 to 20 mA analog communication used in most field instruments today.
EJA series offers two types of fieldbus models, FOUNDATION™ fieldbus Low Voltage Mode and PROFIBUS PA devices, which ensure interoperability between Yokogawa and other manufactures. As for software, the EJA series incorporates two AI function blocks that compute differential and static pressures to allow flexible configuration of instrumentation.

Specifications

  Diaphragm Sealed Gauge Pressure Transmitters
EJA438W/EJA438N
A Capsule
EJA438W
B Capsule
EJA438N
B Capsule
Range -0.1 to 3 MPa
(-15 to 430 psi)
-0.1 to 14 MPa
(-15 to 2000 psi)
-0.1 to 7 MPa
(-15 to 1000 psi)
Span 0.06 to 3 MPa
(8.6 to 430 psi)
0.46 to 14 MPa
(66 to 2000 psi)
0.46 to 7 MPa
(66 to 1000 psi)
Accuracy ±0.2% ±0.2% ±0.2%
Degrees of protection IP67, NEMA 4X, and JIS C0920 immersion proof
Certificates FM, CENECEC ATEX, CSA, TIIS, IECEx
Output 4 to 20 mA DC or FOUNDATION™ fieldbus or PROFIBUS PA 2-wire system with digital communication
Supply voltage BRAIN and HART:10.5 to 42 V DC (10.5 to 30 V DC for Intrinsically safe type)
Fieldbus:9 to 32 V DC (9 to 24 V DC for Entity model and 9 to 17.5 V DC for FISCO model)
Ambient temperature -40 to 60 deg C (-40 to 140 deg F) (general use type)
-30 to 60 deg C (-22 to 140 deg F) (with integral indicator)
It must be within the fill fluid operating temprature range
Process temperature -50 to 300 deg C (-58 to 572 deg F)
It must be within the fill fluid operating temprature range
Maximum working pressure Max. measurement range valve
The working pressure must be within the flange rating.
Mounting Transmitter: 2-inch pipe mounting
Diaphragm seal: flange mounting
Process flange size Flush type: 3-inch (80mm), 2-inch (50mm)
Extended type: 4-inch (100mm), 3-inch (80mm)
Diaphragm material SUS316L, Hastelloy C-276, Tantalum, Titanium
Process flange material S25C, SUS304, SUS316
Housing Cast aluminum alloy or SUS316 equivalent stainless steel (optional)