Skip navigation
Go to Global Navigation
Go to Primary Contents
Go to Site Information

YOKOGAWA

Yokogawa Corporation of America

North America

Font Size
Small Text
Medium Text
Large Text

Multi-sensing, an Evolution in the Silicon Resonant Sensor

EJX510A and EJX530A Absolute and Gauge Pressure Transmitter

Product Information

EJX510A and EJX530A Absolute and Gauge Pressure Transmitter

BRAIN HART FF TUV CE Ctick Logo

EJX Series Differential Pressure Transmitter logo
The high performance absolute and gauge pressure transmitter EJX510A and EJX530A feature single crystal silicon resonant sensor and are suitable to measure liquid, gas, or steam pressure.

The multi-sensing technology provides the advanced diagnostic function to detect such abnormalities as an impulse line blockage or heat trace breakage.
 
The EJX series is available with BRAIN, HART, and FOUNDATION™ fieldbus communication protocols.
 
 
  EJX510A and EJX530A general specifications
PDF
 
  EJX510A and EJX530A User's Manual PDF
Terms of Use for Manuals
 
  List of EJX series pressure transmitter general specifications
 
  List of EJX series pressure transmitter drawings
 

Specifications

  EJX510A and 530A
(Measurement values below are in absolute for EJX510A)
A Capsule B Capsule C Capsule D Capsule
Range EJX510A 0 to 200 kPa
(0 to 29 psi)
0 to 2 MPa
(0 to 290 psi)
0 to 10 MPa
(0 to 1450 psi)
0 to 50 MPa
(0 to 7200 psi)
EJX530A -100 to 200 kPa
(-14.5 to 29 psi)
-0.1 to 2 MPa
(-14.5 to 290 psi)
-0.1 to 10 MPa
(-14.5 to 1450 psi)
-0.1 to 50 MPa
(-14.5 to 7200 psi)
Span 8 to 200 kPa
(1.16 to 29 psi)
0.04 to 2 MPa
(5.8 to 290 psi)
0.2 to 10 MPa
(29 to 1450 psi)
1 to 50 MPa
(145 to 7200 psi)
Accuracy ±0.1% ±0.1% ±0.1% ±0.1%
Degrees of protection IP67, NEMA 4X and JIS C0920 immersion proof
Certificates FM, CENELEC ATEX, CSA, IECEx
Output 4 to 20 mA DC or FOUNDATION™ fieldbus, 2-wire system with digital communication
Supply voltage BRAIN and HART:10.5 to 42 V DC
(10.5 to 30 V DC for Intrinsically safe type)
Fieldbus:9 to 32 V DC
(9 to 24 V DC for Entity and 9 to 17.5 V DC for FISCO)
Ambient temperature -40 to 85 deg C (-40 to 185 deg F) (general use type)
-30 to 80 deg C (-22 to 176 deg F) (with integral indicator)
Process temperature -40 to 120 deg C (-40 to 248 deg F) (general use type)
Maximum overpressure 4 MPa
(580 psi)
4 MPa
(580 psi)
20 MPa
(2900 psi)
75 MPa
(10800 psi)
Mounting Direct mounting/2-inch pipe mounting
Wetted parts material Capsule Hastelloy C-276
Process connection 316L SST, Hastelloy C-276
Housing Cast aluminum alloy or ASTM CF-8M stainless steel (optional)

Get Adobe Reader®Viewing pdf files requires Adobe Reader

Rep Locator

Sales & Support

Field Digital Solutions

Flowmeter Quick Links

Pressure Transmitters Quick Links

Temperature Transmitters Quick Links

Level Transmitters Quick Links

VigilantPlant