- Home>
- Our Businesses:
- Field Instruments:
- Transmitters:
- EJX Pressure/Differential Pressure Transmitters:
- EJX110A Differential Pressure Transmitter:
- EJX120A Draft Range Differential Pressure Transmitter:
- EJX130A High Static Differential Pressure Transmitter:
- EJX210A Flange Mounted Differential Pressure Transmitter:
- EJX310A Absolute Pressure Transmitter:
- EJX430A Gauge Pressure Transmitter>
- EJX440A High Static Gauge Pressure Transmitter:
- EJX510A/EJX530A Absolute and Gauge Pressure Transmitter:
- EJX118A Diaphragm Sealed Differential Pressure Transmitter:
- EJX438A Diaphragm Sealed Gauge Pressure Transmitter:
- EJX115A Low Flow Transmitter:
- EJX910A Multivariable Transmitter:
- EJX930A Multivariable Transmitter:
- EJXMVTool™ EJX-MV Configuration DTM (FSA120):
- EJX630A/EJX610A Gauge and Absolute Pressure Transmitter:
- EJX630A and EJX610A Gauge and Absolute Pressure Transmitter
EJX630A and EJX610A Gauge and Absolute Pressure Transmitter

The high performance in-line gauge pressure transmitter EJX630A and abolute pressure transmitter EJX610A features Yokogawa field proven crystal resonant digital sensor technology to deliver unsurpassed performance and reliability. Measurement Span up to 10,150 psi, 80 msec response time, and ±0.04% accuracy combined with TUV SIL 2 certification yield transmitters that lead the industry.
EJX630A and EKX610A General Specificaitons
EJX630A and EJA610A User Manual
List of EJX series pressure transmitters general specifications
Specificaitons
| EJX630A and 610A (Measurement values below are in absolute for EJX610A) |
|||||
| A Capsule | B Capsule | C Capsule | D Capsule | ||
| Range | EJX610A | 0 to 20 kPa (0 to 29 psi) |
0 to 2 MPa (0 to 290 psi) |
0 to 10 MPa (0 to 1450 psi) |
0 to 70 MPa (0 to 10,150 psi) |
| EJX630A | -100 to 200kPa(-14.5 to 29 psi) | -0.1 to2 MPa ( -14.5 to 290 psi) |
-0.1 to 10 MPa (-14.5 to 1,450 psi) |
-0.1 to 70 MPa (-14.5 to 10,150 psi) |
|
| Span | 2 to 200 kPa (0.3 to 29 psi) |
0.01 to 2 MPa (1.5 to 290 psi) |
0.05 to 10 MPa (7.3 to 1,450 psi) |
0.35 to 70 MPa (50.8 to 10,150 psi) |
|
| Accuracy | ±0.04% | ±0.04% | ±0.04% | ±0.04% | |
| Degrees of protection | IP67, NEMA 4X | ||||
| Certificates | Factory manual (FM), CENELEC, ATEX, IECEx Scheme | ||||
| Output | Digital Communications (FOUNDATION™ fieldbus) | ||||
| Supply voltage | |||||
| Ambient temperature | -40 to +85 deg C (-40 to +185 deg F) (general purpose) -40 to +80 deg C (-40 to +176 deg F) (general purpose with integral indicator) |
||||
| Process temperature | -40 to +120 deg C (-40 to +248 deg F) (general use type) | ||||
| Maximum overpressure | 4 MPa (580 psi) |
16 MPa (2,300 psi) |
25 MPa (3,600 psi) |
105 MPa (15,200 psi) |
|
| Mounting | Direct mount (2-inch pipe mounting bracket available) | ||||
| Wetted parts material | Capsule | Hastelloy C-276 | |||
| Process connection | 316L SST, Hastelloy C-276 | ||||
| Amplifier Housing | Aluminum Alloy (stainless steel available) | ||||