Skip navigation
Go to Global Navigation
Go to Primary Contents
Go to Site Information

YOKOGAWA

Yokogawa Corporation of America

North & Central America

EJA210A, EJA220A Flange Mounted Diff. Pressure Transmitters

The high performance flange mounted differential pressure transmitter models EJA210A and 220A can be used to measure levels of densities of solidifying or precipitating liquids. Both output a 4 to 20 mA DC signal corresponding to the measured differential pressure.
 
The EJA Series is available with BRAIN, HART, FOUNDATION™ fieldbus or PROFIBUS PA communication protocols.
- Excellent performance and stability
  The EJA series uses a silicon resonant sensor formed from monocrystal silicon, a perfect material which has no hysteresis in pressure or temperature changes. The sensor minimizes overpressure, temperature change, and static pressure effects, and thus offers unmatched long-term stability.
 
- Compact and light-weight design
  Half the weight of conventional models thanks to miniaturization of the casing with the amplifier ASIC, pressure cell structure, and flange. The ASIC uses the minimum number of parts and improves the reliability of the amplifier.
 
- Fieldbus communication capability
  Fieldbus is a digital two-way communication system. It is a revolutionary technology for configuring instrumentation control systems and a promising successor to the standard 4 to 20 mA analog communication used in most field instruments today.
EJA series offers two types of fieldbus models, FOUNDATION™ fieldbus Low Voltage Mode and PROFIBUS PA devices, which ensure interoperability between Yokogawa and other manufactures. As for software, the EJA series incorporates two AI function blocks that compute differential and static pressures to allow flexible configuration of instrumentation.
  EJA210A / EJA220A
Liquid Level Differential Pressure Transmitter
M Capsule H Capsule
Range -100 to 100 kPa
(-400 to 400 inH2O)
-500 to 500 kPa
(-2000 to 2000 inH2O)
Span 1 to 100 kPa
(4 to 400 inH2O)
5 to 500 kPa
(20 to 2000 inH2O)
Accuracy ±0.2% ±0.2%
Degrees of protection IP67, NEMA 4X, and JIS C0920 immersion proof
Certificates FM, CENELEC ATEX, CSA, IECEx
Output 4 to 20 mA DC or FOUNDATION™ fieldbus or PROFIBUS PA 2-wire system with digital communication
Supply voltage BRAIN and HART:10.5 to 42 V DC (10.5 to 30 V DC for Intrinsically safe type)
Fieldbus:9 to 32 V DC (9 to 24 V DC for Entity model and 9 to 17.5 V DC for FISCO model)
Ambient temperature -40 to 85 deg C (-40 to 185 deg F) (general use type)
-30 to 80 deg C (-22 to 176 deg F) (with integral indicator)
Process temperature -40 to 120 deg C (-40 to 248 deg F) (general use type)
Maximum working pressure Flange rating pressure
Mounting Flange mounting
Process flange size EJA210A: 3-inch (80mm), 2-inch (50mm)
EJA220A: 4-inch (100mm), 3-inch (80mm)
Diaphragm material
(High side)
SUS316L, Hastelloy C-276, Tantalum
Process flange material S25C, SUS304, SUS316
Housing Cast aluminum alloy or SUS316 equivalent stainless steel (optional

*Note: Large size font is recomended for viewing.

Model Application Type Capsule Measurement Span Maximum Working Pressure
kPa inH2O MPa psi
fld-eja110-h50-01.jpg
EJA110A
Differential
Pressure
Traditional-
Mounting*1
L
M
H
V
0.5 to 10
1 to 100
5 to 500
0.14 to 14MPa
2 to 40
4 to 400
20 to 2000
20 to 2000 psi
16*3
16   
16   
16   
2250*3
2250   
2250   
2250   
fld-eja115-h50-01.jpg
EJA115
Flow Integral
Orifice
L
M
H
1 to 10
2 to 100
20 to 210
4 to 40
8 to 400
80 to 830
3.5
14
14
500
2000
2000
fld-eja118-50-01.jpg
EJA118W
EJA118N
EJA118Y
Differential
Pressure
& Liquid
Level
with
Remote
Seals
Extended
Flush
Combination
M
H
2.5 to 100
25 to 500
10 to 400
100 to 2000
Based on Flange Rating
fld-eja120-h50-01.jpg
EJA120A
Draft
Range
Traditional-
Mounting*1
E 0.1 to 1 0.4 to 4 50 kPa 7.25
fld-eja130-h50-01.jpg
EJA130A
Differential
Pressure
& Liquid
Level
Traditional-
Mounting*1
M
H
1 to 100
5 to 500
4 to 400
20 to 2000
32
32
4500
4500
fld-eja210-50-01.jpg
EJA210A
EJA220A
Liquid
Level,
Closed
or Open
Tank
Flush
Extended
M
H
1 to 100
5 to 500
4 to 400
20 to 2000
Based on Flange Rating
fld-eja310-h50-01.jpg
EJA310A
Absolute
(Vacuum)
Pressure*2
Traditional-
Mounting*1
L
M
A
0.67 to 10
1.3 to 130
0.03 to 3 MPa
2.67 to 40
0.38 to 38 inHg
4.3 to 430 psi
10 kPa
130 kPa
3000 kPa
40 in H2O
18.65
430
fld-eja430-h50-01.jpg
EJA430A
Gauge
Pressure
Traditional-
Mounting*1
A
B
0.03 to 3 MPa
0.14 to 14 MPa
4.3 to 430 psi
20 to 2000 psi
3
14
430
2000
fld-eja438-50-01.jpg
EJA438W
EJA438N
Gauge
Pressure
with Remote
Seal
Flush A
B
0.06 to 3 MPa
0.46 to 14 MPa
8.6 to 430 psi
66 to 2000 psi
Based on Flange Rating
Extended A
B
0.06 to 3 MPa
0.46 to 7 MPa
8.6 to 430 psi
66 to 1000 psi
fld-eja440-h50-01.jpg
EJA440A
High
Gauge
Traditional-
Mounting*1
C
D
5 to 32 MPa
5 to 50 MPa
720 to 4500 psi
720 to 7200 psi
32
50
4500
7200
fld-eja510-h50-01.jpg
EJA510A
EJA530A
EJA530A
/HAC
Absolute
& Gauge
Pressure*2
Direct-
Mounting
A
B
C
D
10 to 200
0.1 to 2 MPa
0.5 to 10 MPa
5 to 50 MPa
1.45 to 29 psi
14.5 to 290 psi
72.5 to 1450 psi
720 to 7200 psi
200 kPa
2
10
50
29
290
1450
7200
*1: Traditional-Mounting is 1/4NPT or Rc1/4 process connections (1/2NPT or Rc1/2 with process adapter).
*2: Measurement values in absolute for absolute pressure transmitter.
*3: When combined with Wetted parts material code H, M, T, A, D, and B, the value is 3.5 MPa (500 psi).