ADMAG AXW

The ADMAG AXW is a high-quality, reliable magnetic flowmeter. Certified to SIL2 to comply with functional safety standard IEC 61508, it can be used in safety instrumented systems up to SIL2 in simplex configuration and SIL3 in redundant configuration.

Details

What Is the ADMAG Total Insight (TI) AXW?

The ADMAG Total Insight (TI) AXW is an electromagnetic flow meter featuring enhanced settings for customized setups, pre-defined trend views, and multiple configuration sets for fast changeover through microSD card. The ADMAG TI AXW comes standard with built-in verification, reducing total cost of ownership.

Some of the highlights of the ADMAG TI AXW include:

  • Diameter: 1” to 72” (25mm to 1800mm)*
  • Liner materials: PTFE, Variety of rubbers
  • Accuracy: ±0.35% of flow rate
  • Ideal for water supply/sewage applications and general industrial process lines
  • Submersible version available 1” to 72” (25 to 1800mm)

ADMAG Converters & Related Products:

AXW4A ADMAG TI Remote Converter
AXF11 Magnetic Flow Converter
FieldMate

*Models that require a diameter of 44" and above will feature a different design than pictured.

What Are the Benefits of the ADMAG Total Insight (TI) AXW?

 

Simplified Selection

Selection Tool
In just a few clicks, find the best unit for your process based on required functionality and specifications. (Releasing soon.)

Expert Guide

Wizard Function
Basic parameters that are commonly set such as flow rate span, totalizer/pulse output, and display are grouped together under the Easy Setup Wizard. This reduces the time taken for device startup.

Multiple Languages
Select from nine different language options: English/French/German/Italian/Spanish/Portuguese/Russian/Chinese/Japanese.

Cable Connection Check Function
For multiple remote type units that are wired and installed at the same time, often a wiring error occurs. Yokogawa has developed a method for detecting a wiring error based on changes in the signal waveforms when excitation is on and off 

Process Guard

Data Logging Function
Log up to four different process variables (electrode A, electrode B, adhesion level, flow noise, velocity, volume flow, mass flow, calorie) and save onto the micro SD card. A quick troubleshooting analysis can be conducted by looking at the trend curve and alarms, and data can be downloaded and saved to analyze offline.

NAMUR Function
A total of 28 system and process alarms can be individually classified according to NAMUR NE 107. The user can adapt the action of each alarm individually to meet process requirements and prevent unnecessary alarms from distracting plant operators.

Maintenance Manager

Built-in Verification
Three levels of verification functions are available, including a built-in verification function for ADMAG TI converters that checks the magnetic circuit, excitation circuit, computing circuit, alarm history, and cable connection.

Additional functions include standard and enhanced verification that can generate the report based on the displayed results of the equipment and perform additional checks using peripheral devices. The built-in verification and standard verification are within ±5% of factory accuracy, and the enhanced verification is within ±2% of factory accuracy, guaranteeing the health of the equipment.

Data Mobility

Data Transfer Using microSD Card
A unique feature of the microSD allows users to back up parameter setting, trend data storage, record various data measurements for offline analysis, duplicate multiple units, and save all device data and configuration data to a PC.

Advanced Flexibility

Backward Compatibility
Backward compatibility in the ADMAG TI AXW allows users to combine new ADMAG TI AXW sensors and transmitters with older ADMAG AXW flow meters, making plant lifecycle management easier and less costly.

Worldwide Approvals
The ADMAG TI series offers explosion proof, SIL, EMC, NAMUR and multiple communication protocols to meet the needs of all markets and applications.

Various I/O Combinations
The ADMAG TI series offers multiple combinations of I/O (includes current input) and communication types. This gives the flexibility to utilize the process information for better control in your application.

Some examples are 2 analog points (2 output or 1 output and 1 input) or 2 digital points (2 pulse output, or 1 pulse input and 1 input/output).

Nominal Pipe Size 500 to 1800 mm (20 to 72 inch) (General-purpose / Submersible)
Power Supply 100 to 240 V AC or 100 to 120 V DC, 24 V AC / DC [ combined with AXFA11 ]
Output Signals One current output, One pulse output, One alarm output, Two status outputs [ combined with AXFA11 ]
Fluid Temperature -10 to +120 deg.C (+14 to +248 deg.F) [ depends on model type ]
Ambient Temperature -10 to +60 deg.C (+14 to +140 deg.F) [ depends on model type ]
Accuracy ±0.35% of rate
±0.5% of rate
[ depends on model type ]
Fluid Conductivity 20 μS /cm or larger [ depends on model type ]
Lining Material Fluorocarbon PTFE
Natural hard rubber
Natural soft rubber
Polyurethane rubber
Electrode Material JIS SUS316L (AISI 316L SS Equivalent) Hastelloy C276 Equivalent
Process Connection ASME, AWWA, EN, JIS and AS

* Please refer to General Specifications in detail.

Resources

Sizes 1000 mm (40") and below: 20 µS/cm or greater Sizes 1100 mm (44") and above: 50 µS/cm or greater 
ADMAG TI autozero or zero adjustment is carried out to ensure that the output for zero flow is 0% (i.e., 4 mA). Although adjustment to zero is performed at the manufacturing plant prior to shipment, this procedure must be carried out once again follo...
Edition 1
Overview:

ADMAG TI autozero or zero adjustment is carried out to ensure that the output for zero flow is 0% (i.e., 4 mA). Although adjustment to zero is performed at the manufacturing plant prior to shipment, this procedure must be carried out once again following the installation of piping in order to match the magnetic flowmeter to its operating conditions.

They help remove stray energy or noise as it builds up in the flow process by grounding it. They can even help protect the magmeter liner from damage in harsher processes.
Edition 1
Overview:

They help remove stray energy or noise as it builds up in the flow process by grounding it. They can even help protect the magmeter liner from damage in harsher processes.

Downloads

Engineering Tools

2D/3D Configurator

News

Looking for more information on our people, technology and solutions?

Contact Us

Top