Settling Time
and Accuracy |
Settling time |
Within 5 hours
(Operational state is reached in about 2 hours) |
| Accuracy |
Static: ±0.25 deg.x sec (Latitude)
Dynamic: ±0.75 deg.x sec (Latitude) |
| Follow up accuracy |
0.1 deg. or less |
| Max. follow up speed |
30 deg./s |
Environmental
(Normal use) |
Permissible angle |
±40 deg.(Roll), ±40 deg. (Pitch) |
| Ambient temperature |
-10 deg.C to +55 deg.C |
| Power Supply |
Main |
24V DC
AC adapter (Option), type MKR027 is available on
100V/110V/115V/220V AC 50/60Hz single-phase |
| Alarm |
24 V DC |
| Signal Inputs |
External heading |
IEC61162-1 (NMEA0183) |
1 circuit |
| Options (Available on adding C.Operation
unit, type MKR024) |
Automatic
speed error correction |
Optional |
| Latitude |
IEC61162-1 (NMEA0183) |
1 circuit |
| Ship's speed |
200 P/nm or IEC61162-1 (NMEA0183) |
1 circuit |
External heading
(For deviation alarm) |
IEC61162-1 (NMEA0183)
(Supplied to C.Operation unit, MKR024) |
1 circuit |
| Signal Outputs |
Heading data for repeater compasses |
3 circuits |
| Heading data for steppers |
1 circuit |
| Serial data |
IEC61162-1 |
1 circuit |
| IEC61162-1/-2 selective |
2 circuits |
| Gyro. running (Close contact when running) |
1 circuit |
Alarms (Open contact
when abnormal) |
System failure |
1 circuit |
| No voltage |
1 circuit |