Settling Time
and Accuracy |
Settling time |
Within 5 hours
(Operational state is reached in about 2 hours) |
| Accuracy |
Static: ±0.25 deg.x sec (Latitude)
Dynamic: ±0.75 deg.x sec (Latitude) |
| Follow up accuracy |
0.1 deg. or less |
| Max. follow up speed |
30 deg./s |
Environmental
(Normal use) |
Permissible angle |
±40 deg.(Roll), ±40 deg. (Pitch) |
| Ambient temperature |
-10 deg.C to +55 deg.C |
| Power Supply |
Main |
100V/110V/115V/220V AC 50/60Hz single-phase
24V DC (For back up power) |
| Alarm |
24 V DC |
| Signal Inputs |
Automatic
speed error correction |
Latitude: IEC61162-1 (NMEA0183) |
1 circuit |
Ship's speed: 200 P/nm or IEC61162-1
(NMEA0183)
|
1 circuit |
| External heading |
IEC61162-1 (NMEA0183) |
1 circuit |
| Signal Outputs |
Heading data for repeater compasses |
8 circuits |
| Heading data for steppers |
4 circuits |
| Serial data |
IEC61162-1 |
1 circuit |
| IEC61162-1/-2 selective |
2 circuits |
| Analog heading data |
Heading signal |
1 circuit |
| Quadrant signal |
1 circuit |
| Turn rate signal |
3 circuits |
| Gyro. running (Close contact when running) |
1 circuit |
Alarms (Open contact
when abnormal) |
System failure |
1 circuit |
| Master compass failure |
1 circuit |
| No voltage |
1 circuit |
| Heading deviation signal (Close contact when excessive) |
1 circuit |