Two-way Communication Feature of FOUNDATION fieldbus™ Reduce Total Cost of Ownership

Download (513 KB)

Introduction

Two-way Communication Feature of FOUNDATION fieldbus™ Reduce Total Cost of Ownership

FOUNDATION fieldbus technology enables all-digital, two-way communications between field devices and control systems. While the advantages of using digital communications for sharing maintenance-related device information with an asset management system are well known, there are other benefits from using the FOUNDATION fieldbus technology. This paper introduces an application that relies on the two-way communications capability of FOUNDATION fieldbus.

Expected Benefits

Reduced total cost of ownership (TCO) by eliminating the need for local display panels.

Application

As shown in figure 1, gas flow is calculated by a remote terminal unit (RTU) using process data received from a transmitter. Although such data can be monitored on a SCADA system, a display panel is required to monitor the gas flow on-site.

Fig.1 System configuration using 4-20mA

Fig.1 System configuration using 4-20mA

What is 4-20mA?
4-20mA is an analog signal that has been used as a process signal for decades. It is limited to sending process data.

Solution

With conventional 4-20 mA communications, it is impossible to send the data calculated by an RTU back to a transmitter because this technology only supports one-way communications. However, as shown in figure 2, gas flow data calculated by an RTU can be sent back to a transmitter using the two-way communications capability of FOUNDATIONfieldbus. The gas flow data can thus be displayed on the transmitter's LCD, eliminating the need for the use of a local display panel or hand-held terminal.

Fig.2 System configuration using FOUNDATION fieldbus

Fig.2 System configuration using FOUNDATION fieldbus

Process data measured by transmitter (INDEX 1-3), output data calculated on RTU (INDEX 4-6) and configuration parameters set to RTU (INDEX 7-10) are periodically displayed on transmitter's LCD with measurement units and comments.

What is FOUNDATION fieldbus?
FOUNDATION fieldbus provides all-digital communication. It provides two way communications between devices and their information in addition to process data.

Customer Site

The United States Department of the Interior Bureau of Land Management (BLM) published a notice of the minimum standards and requirements for the sale and allocation Electronic Flow Computers (EFCs) in 2008. The requirements for EFC displays are mentioned in this notice. "The display shall be readable on site without the need for data collection units, laptop computers or any special equipment, shall be onsite, and shall be in a location that is accessible to the BLM."

To meet these requirements, Yokogawa Corporation of America proposed using the transmitters' LCD as a substitute for local display panels, reducing the total cost of the ownership (TCO) of the projects.

Industries

  • Offshore (FPSO FLNG & FSRU)

    Offshore exploration and production requires maximum uptime under harsh conditions. Manned and unmanned facilities need reliable integrated control and safety systems (ICSS) with advanced remote monitoring capabilities. Yokogawa has state-of-the-art technology and extensive experience in executing offshore projects of all sizes and automation levels of complexity.

    See More
  • Oil & Gas

    Yokogawa has a wealth of experience in every part of the oil and gas business, from offshore and onshore facilities to pipelines, terminals, and deepwater operations. We provide solutions that enhance safety, ensure accurate and reliable operation, and increase plant efficiency.

    See More
  • Upstream

    The upstream industry includes offshore and onshore activities including wellhead automation, fractionation, completion, and separation to recover and prepare underground or underwater crude oil and natural gas.

    As petroleum is brought to the surface, it must be separated prior to transport. Primary and secondary separation stages commonly distribute gas flow, water flow, and oil flow in three phase separation. Gas movement requires pipeline and can include a fractionation process in the upstream stage prior to movement. Liquids can be placed into a tanks or pipelines and sent for processing, requiring accurate level measurements.

    See More

Related Products & Solutions

  • EJX910A

    This transmitter precisely measures differential pressure, static pressure, and process temperature; then uses these values in a high-perfomance on-board flow computer to deliver fully compensated Mass Flow.

    See More
  • EJX930A

    Designed specifically for high static pressure applications, this transmitter precisely measures differential pressure, static pressure, and process temperature; then uses these values in a high-perfomance on-board flow computer to deliver fully compensated Mass Flow.

    See More
  • FCJ All-in-one PLC/RTU

    The brick type model FCJ autonomous controller fulfills the basic requirements of the utility control. It also provides the reliability for the SCADA communication with network redundant capability.

    See More
  • Pressure Transmitters

    The accurate and stable measurement of process pressure with Yokogawa Pressure Transmitters supports the safe, reliable, and profitable operation of your plant.

    See More

Top