Measuring Temperature in a Rotating Furnace

Application

Measuring temperature in a rotating furnace using the YTMX580 Multi-Input Temperature Transmitter

Background and customer requirements

The customer uses a rotating furnace in their manufacturing of titanium oxide. They wish to install multiple temperature sensors directly on the rotating furnace in order to measure the internal temperature with high accuracy.

Solutions

Install a YTMX580 on the side of the rotating furnace that can wirelessly transmit measured values from multiple temperature sensors.

Benefits

  • The YTMX580 allows wireless transmission of up to 8 data sources
  • Direct temperature sensors provide the highest accuracy
  • Wireless transmission means no wiring from the rotating furnace
  • Battery powered—eliminates power cords and wires

Measuring Temperature in a Rotating Furnace Using the YTMX580

Industrieën

  • Chemie

    Chemische fabrieken zijn afhankelijk van continu- en batch-productieprocessen die elk verschillende eisen stellen aan een besturingssysteem. Een continu proces vereist een robuust en stabiel besturingssysteem dat niet faalt en de productielijn doet stilvallen. Bij een batchproces ligt de nadruk ligt op een besturingssysteem dat een grote flexibiliteit biedt bij het aanpassen van o.a. formules en procedures. Beide soorten systemen moeten worden beheerd naar aanleiding van de productiegeschiedenis rond de kwaliteit van het product, en in staat zijn om niet-routinematige werkzaamheden uit te voeren. Met een uitgebreide productportfolio, ervaren systeemingenieurs en wereldwijde verkoop- en servicenetwerk heeft Yokogawa een oplossing voor elk fabrieksproces.

    Meer
  • Petrochemie

    De behoeften van petrochemische bedrijven zijn zeer divers. Om voorop te blijven lopen in de huidige, sterk concurrerende markt, streven producenten naar verbetering van kwaliteit en productiviteit. Yokogawa biedt op maat gemaakte oplossingen voor deze behoeften op basis van haar lange en brede ervaring op dit gebied.

    Meer

Gerelateerde producten & oplossingen

  • YFGW410 Field Wireless Management Station

    YFGW410 Field Wireless Management Station has system manager/security manager/gateway function based on ISA100.11a, and combining this with Field Wireless Access Point(YFGW510) and/or Field Wireless Media Converter(YFGW610) composes the field wireless system.

    Meer
  • YFGW520 Field Wireless Access Point

    YFGW520 Field Wireless Access Poin has backbone router function based on ISA, and combining this with Field Wireless Management Station (YFGW410) and/or Field Wireless Media Converter (YFGW610) composes the field wireless system.

    Meer
  • YFGW710 Field Wireless Integrated Gateway

    YFGW710 Field Wireless Integrated Gateway comply to the wireless communications standard ISA100.11a for industrial automation of International Society of Automation (ISA), and relays ISA100 Device data to the system via integrated backbone router. Single unit of YFGW710 has integrated functions of backbone router, system manager, security manage, and gateway.

    Meer
  • YTMX580 Multi-Input Temperature Transmitter

    YTMX580 can accept inputs from up to 8 points of measurement such as thermocouples (8 types: K, E, J, etc.) or RTD signals (3 types: Pt100, etc.), converting the corresponding measurement input values to a wireless signal. It can also accept DC voltage, resistance, and 4 to 20 mA DC signal input.

    Meer
  • Field Wireless

    The flexibility of wireless solutions enables less investment in infrastructure while providing greater insights into plant operations.

    Meer

Top