ORP Sensors

Oxidation Reduction Potential (ORP) electrodes and sensors are the sensing portions of a ORP measurement. Various installation options including retractable, flow thru, immersion, and direct insertion. Proper ORP electrode/sensor selection is critical for optimal measurement results.

  • The PH20, FU20 and FU24, all-in-one pH and ORP, sensors show how Yokogawa applies the motto "Simple is best" to sensor technology.

  • All-In-One pH and ORP digital smart sensor that keeps the motto "Simple is best" while combing the sensor with built-in intelligence and direct digital communication. 

  • Yokogawa's pH and ORP analyzers are highly reliable. They feature advanced functions and are useful for a wide variety of applications including water quality management in a broad range of production processes and in medium-sized wastewater treatment plants, or as general pH and ORP control systems.

  • The cation differential pH and ORP sensors were designed for difficult applications where conventional sensors are ineffective. These include measurements such as brine solutions to applications as diverse as electrolysis processes and cheese manufacturing.

  • The heart of a pH measuring loop is the electrode system. Yokogawa has designed a wide range of electrodes to ensure this heart keeps beating under the most severe conditions.

  • Achieving accurate and reliable readings using a traditional pH analyzer is challenging, however with the right equipment stable and accurate pure water pH measurements can be accomplished. Yokogawa's specialized bellomatic pH sensor is proven best solution for high purity water applications. For those individuals that do not like the maintenance of refilling sensors, then the FU24 which incorporates the successful patented bellow system in an All-in-one body is the ideal solution.

  • PH4/OR4 pH/ORP Sensor Series Allows pH/ORP measurement under severe conditions, such as where the process fluid is heavily contaminated or contains sulfide. PH4/OR4 Sensor Series meets the simple apparatus requirements.

  • The PH71/PH72 pH and/or ORP meter is a Compact, Easy-to-use, Drip proof – Ideal for Field Use. Features "One-Touch Calibration" and Temperature Compensation. Laboratory-Grade Intelligent pH Meters – Sized and Priced to Fit in Your Pocket

  • Yokogawa has invested considerable design and development time in producing a full range of fittings with particular emphasis on designs that reduce installation and maintenance time and consequently save operation costs.

  • The immersion fittings are designed for either pH or ORP (Redox) measurements in tanks, open vessels and drains. They have a "hoisting cable" for easy maintenance.

  • On-line measurements often present extra challenges, especially when routine maintenance is required. The PR10 is ideally suitable for applications where the sensors must be removed without interrupting or shutting down the process. Without any special tools the PR10 can be retracted safely from the process at pressures up to 5 bar (72 psi). Using the PR10 allows us to place any dissolved oxygen sensor that has a PG13.5 connenction into a retractable assembly.

  • Yokogawa provides several types of holders, for which cleaners can be added, allowing customers to build reliable and easy-to-maintain measuring systems by selecting the right holders and cleaners for the conditions of applications.

  • Between measuring plant and control room, especially when the distance between these places is greater than the length of the standard appropriate electrode cables, the connecting equipment can be an expedient method for connecting sensor cables to a measuring instrument.

  • Buffer solutions are needed as an indispensable tool for maintaining an accurate pH measurement. Buffer solutions are used as references points for calibration and adjustment of pH measurements to compensate for aging and deterioration.

Overview:

Current trend for increasing mercury awareness throughout the public sector has caused the government to take action. Recently, the Environmental Protection Agency (EPA) has focused their efforts on controlling mercury levels produced in various coal fired power plants. Based on information from several case studies, the EPA developed the Mercury and Air Toxics Standards to cut back mercury emissions. The most popular technology utilized by coal plants to meet the new standards is a scrubber which cleans the off gas from the combustion process. ORP sensors can further monitor the effluent from these scrubbers to ensure optimal mercury emission levels are achieved. By closely monitoring the mercury concentrations in the effluent, plant managers will be able to easily confirm their plants are meeting the EPA's standards.

Industries:
Overview:

To facilitate the accurate measurement of pH, and its presentation as a scale, a range of "standard liquids" or "buffer solutions" are used. These liquids, whose constituents are accurately defined, have known stable values. Although in the preceding text the relationship to hydrogen ions has been made, research has shown, that the activity of hydroxonium ions (H30+) is more relevant.

Looking for more information on our people, technology and solutions?