Magnetic Flowmeters

History of YOKOGAWA's Magnetic Flowmeters

YOKOGAWA's magnetic flowmeter is supported by a long history of more than half a century. We added innovative specifications in each era, and have always lead the industry. The consistent policy of YOKOGAWA's magnetic flowmeter is to have high performance and high quality.

The world's first dual frequency excitation method adopted in the ADMAG AM series announced in 1988 pushed the stability measurement of the magnetic flowmeter to a higher standard. Capacitance type magnetic flowmeter ADMAG CA series has made it possible to measure low conductivity fluid and insulating adhesive fluid. ADMAG AXR series realized overwhelming high performance with limited power supply voltage of two-wires.

And now, it is the birth of ADMAG TI series to adopt the "Total Insight" concept and totally support the product life cycle.

 

New Series ADMAG Total Insight(ADMAG TI) All Product

Image Zoom

 

Product Introduction

  • ADMAG Total Insight can measure flow with high accuracy.
    • The standard specification achieves an accuracy of ± 0.3% (reading value).
    • Supporting problem solution with abundant diagnostic functions.
    • It is a successor to ADMAG AXF and can be replaced.
      *For some specifications, we have discontinued sales.

  • The magnetic flowmeter CA Series can measure the high-concentration slurry fluids and insulator-adhesive fluid.
    • There is no electrical noise since the slurry does not collide with the electrode.
    • The non-wetted electrode type ensures stable flow measurement even if deposits form on the measurement tube.
    • The flow rate can be measured from conductivity 0.01μS/cm.
    • Abundant verification function contribute to problem solving.
    • Visibility is excellent with a dot matrix display.
    • Adopts HART communication.

 

Fluid Types ADMAG Total Insight CA Series
Corrosive A A
Slurry A A
Adhesion B A
Low Conductivity B A

A: Usable, B: Usable period may be short

 

  ADMAG Total Insight CA Series
Measurable
Conductivity
Above 1 μS/cm Above 0.01 μS/cm
Electrode Type Wetted type Capacity type
Accuracy
(Reading Value)
ADMAG AXG
± 0.3 %
ADMAG AXW
± 0.35 %
± 0.5 %
Size ADMAG AXG
2.5 to 500 mm
ADMAG AXW
25 to 1,800 mm
15 to 200 mm
Wiring 4-wires 4-wires
Communication
Protocol
HART 7, BRAIN, Modbus,
FOUNDATION Fieldbus, PROFIBUS PA, EtherNet / IP
HART 7
Diagnostic
Function
Application Diagnostic
- Flow Noise Diagnosis
- Low Conductivity Diagnosis
- Electrode Insulation Deterioration Diagnosis
- Electrode Adhesion Detection
- Sensor Empty Check
- Wiring Connection Diagnosis

Verification Function
- Built-in/Standard/
- Enhanced Verification
Verification Function
- Built-in/Standard
- Enhanced Verification

 

Product Lineup

Kaynaklar

Genel Bakış:
  • To bring the customer a real-time monitoring and management capability, Yokogawa installed STARDOM (FCJ), flow meters, and transmitters at key points throughout the distribution network.
  • The STARDOM FCJ controllers achieved an accurate water loss management system while keeping the running costs to a minimum.
Genel Bakış:

Water Supply Treatment
FAST/TOOLS, STARDOM, Flowmeters, Liquid Analyzers

  • Bali's water treatment plant decided to employ the latest reliable control system in order to increase availability and quality of operation.
  • Centralized control system using FAST/TOOLS provides the sophisticated and flexible operation.
Uygulama Notları
Genel Bakış:

With the high temperatures, pressures, and levels of dissolved organics that are encountered, the ADMAG AXF flow meter design is ideal for use in all phases of the chemical recovery process.

Endüstriler:
Genel Bakış:

The pulp and paper industry has very aggressive and challenging applications for magmeters. There are corrosive Zone chemicals, high temperatures and pressures, and abrasive slurries. Yokogawa can provide the most reliable and accurate meters for each application.

Endüstriler:
Genel Bakış:

Magnetic Flowmeter dual frequency excitation provides immunity to slurry noise by good stability and accuracy, determining the maintenance timing can be recognized by monitoring of electrodes.

Endüstriler:
Genel Bakış:

Caustic soda and hydrochloric acid, produced in electrolyzer plants, are fundamental materials used in varieties of industries; chemicals, pharmaceuticals, petrol-chemicals, pulp and papers, etc. Profit is the result of the effective production with minimized running / maintenance cost. Proper control of the process brings you stabilized quality of products with the vast operational profit.

Endüstriler:
Genel Bakış:

The new digester magmeter enabled accurate and stable flow measurement of the black liquor circulation line, helping the user to stabilize the cooking degree that determines the quality of the chip digesting process.

Endüstriler:
Uygulama Notları
Genel Bakış:

The ADMAG AXR is the world's first 2-wire magnetic flow meter which employs the unique "Dual Frequency Excitation Method," achieving 0.5% of rate of best-in-class accuracy and excellent stability for process measurement. In addition, the newly developed AXR key technologies," achieves the same level of noise immunity as 4-wire type under the fluid condition change and delivers enough performance to meet the requirement to apply in the control loop.

Uygulama Notları
Genel Bakış:

Yokogawa's ceramic liner can offer the customer superior resistance to thermal shock and the failure that can occur due to liner cracking. This is due to Yokogawa's use of 99.9% pure Al2O3 for the liner.

Endüstriler:
Genel Bakış:

Continuous technology improvement is ongoing in the pulp & paper industry to obtain the best possible performance. The improved plant performance translates to the higher quality improvement and lower cost, and simultaneously environmental friendly plant operation.

Endüstriler:
Genel Bakış:

This paper introduces the ADMAG AXR 2-wire magnetic flomwmeter solution for dust collection water application of steel converter.

Endüstriler:
Genel Bakış:

The control of the world's water resource is arguably one of the most important issues. Water demand from industry and domestic users is set to rise throughout the industrialized world. Yokogawa has been applying minimized maintenance measurement systems.

Uygulama Notları
Genel Bakış:

Recently, air pollution legislations such as the Clean Air Act to reduce the amount of air pollution are increasing worldwide. The Clean Air Act address numerous air quality problems. One of these problems is acid rain caused by sulfur dioxide and nitrogen oxide emissions from fossil-fueled power plants and other industrial and transportation sources.

Genel Bakış:

The use of recycled oil as an energy source presents a significant processing problem. ADMAG CA has been shown to provide reliable and stable flow measurement of recycled oil containing water.

Yokogawa Teknik Raporları
Genel Bakış:

More than half a century has passed since Yokogawa developed Japan's first magnetic flow meter for industrial use in 1955, and today, Yokogawa's magnetic flow meters are widely used in a variety of applications thanks to features such as low pressure loss and maintenance-free operation due to no obstacles and moving parts in the fluid flowing pipeline.

Endüstriler:
Yokogawa Teknik Raporları
Genel Bakış:

After having undergone several improvements, magnetic flow meters have become highly accurate and reliable and are widely used in the industrial instrument field today. Magnetic flow meters consist of a detector and a converter, with the principle of the detector adopting Faraday's electromagnetic induction law.

Yokogawa Teknik Raporları
Genel Bakış:

In 1988, Yokogawa launched the ADMAG series of magnetic flow meters with increased resistance to fluid noise and zero stability, employing dual frequency excitation which was developed based on its long-cultivated technology for flow measurement. Since then, the ADMAG family has augmented its application range with such models as explosion-proof and integral types, and a capacitance type.

Genel Bakış:

Control Engineering Asia, March 2012

Enabling the operational benefits of two-wire magnetic flow meters while maintaining the performance levels associated with traditional four-wire devices.

İndirilenler

İnsanlarımız, teknolojimiz ve çözümlerimiz hakkında daha fazla bilgi mi arıyorsunuz?

Bizimle İletişime Geçin

En üst