Oxidation Reduction Potential (ORP) electrodes and sensors are the sensing portions of a ORP measurement. Various installation options including retractable, flow thru, immersion, and direct insertion. Proper ORP electrode/sensor selection is critical for optimal measurement results.

  • The PH20, FU20 and FU24, all-in-one pH and ORP, sensors show how Yokogawa applies the motto "Simple is best" to sensor technology.

  • All-In-One pH and ORP digital smart sensor that keeps the motto "Simple is best" while combing the sensor with built-in intelligence and direct digital communication. 

  • The cation differential pH and ORP sensors were designed for difficult applications where conventional sensors are ineffective. These include measurements such as brine solutions to applications as diverse as electrolysis processes and cheese manufacturing.

  • The heart of a pH measuring loop is the electrode system. Yokogawa has designed a wide range of electrodes to ensure this heart keeps beating under the most severe conditions.

  • Achieving accurate and reliable readings using a traditional pH analyzer is challenging, however with the right equipment stable and accurate pure water pH measurements can be accomplished. Yokogawa's specialized bellomatic pH sensor is proven best solution for high purity water applications. For those individuals that do not like the maintenance of refilling sensors, then the FU24 which incorporates the successful patented bellow system in an All-in-one body is the ideal solution.

  • The PH71/PH72 pH and/or ORP meter is a Compact, Easy-to-use, Drip proof – Ideal for Field Use. Features "One-Touch Calibration" and Temperature Compensation. Laboratory-Grade Intelligent pH Meters – Sized and Priced to Fit in Your Pocket

  • Yokogawa has invested considerable design and development time in producing a full range of fittings with particular emphasis on designs that reduce installation and maintenance time and consequently save operation costs.

  • The immersion fittings are designed for either pH or ORP (Redox) measurements in tanks, open vessels and drains. They have a "hoisting cable" for easy maintenance.

  • On-line measurements often present extra challenges, especially when routine maintenance is required. The PR10 is ideally suitable for applications where the sensors must be removed without interrupting or shutting down the process. Without any special tools the PR10 can be retracted safely from the process at pressures up to 5 bar (72 psi). Using the PR10 allows us to place any dissolved oxygen sensor that has a PG13.5 connenction into a retractable assembly.

  • Between measuring plant and control room, especially when the distance between these places is greater than the length of the standard appropriate electrode cables, the connecting equipment can be an expedient method for connecting sensor cables to a measuring instrument.

  • Buffer solutions are needed as an indispensable tool for maintaining an accurate pH measurement. Buffer solutions are used as references points for calibration and adjustment of pH measurements to compensate for aging and deterioration.

  • These sensors feature the latest innovations in pH glass formulation, reference systems, and reference electrolytes. They offer supperior accuracy and stability, even after repeated sterilizations.

  • The PH87 retractable assembly is suitable for "Hot-Tap" service, allowing for removal from a pressurized process line or vessel without interrupting the flow or draining the tank.  The housing assemblies are constructed of chemically resistant titanium sheathes and are used with Model PH97 rugged sensors.  

  • The pneumatic retractable holder EXAtrac RF20 (Extrac 810 and 820) is made for installation of 12mm sensors on tanks or pipelines where the sensor has to be removed without interruptions or shutdowns and in the hash applications where frequent cleaning is of vital importance for a good pH measurement.

  • A pH electrode is as good as its maintenance; this is especially true in harsh environments. For industrial applications and particularly for automatic process measurements it is of the greatest importance that the sensitive part of a glass electrode and the diaphragm of a reference electrode are kept clean.

Overview:

Current trend for increasing mercury awareness throughout the public sector has caused the government to take action. Recently, the Environmental Protection Agency (EPA) has focused their efforts on controlling mercury levels produced in various coal fired power plants. Based on information from several case studies, the EPA developed the Mercury and Air Toxics Standards to cut back mercury emissions. The most popular technology utilized by coal plants to meet the new standards is a scrubber which cleans the off gas from the combustion process. ORP sensors can further monitor the effluent from these scrubbers to ensure optimal mercury emission levels are achieved. By closely monitoring the mercury concentrations in the effluent, plant managers will be able to easily confirm their plants are meeting the EPA's standards.