Flue Gas Desulfurization Systems - Process West

Download (799 KB)

Flue Gas Desulfurization SystemsRecent or pending air pollution legislation to reduce the amount of air pollutants is increasing worldwide. In the U.S., The Clean Air Act address numerous air quality problems. One of these problems is acid rain (much of which falls in Canada) caused by sulfur dioxide and nitrogen oxide emissions from fossil-fueled power plants and other industrial and transportation sources. Sulfur oxides and nitrogen oxides (NOx) are recognized as harmful pollutants and great efforts are underway to remove these toxic gases. Under emission regulatory requirements and legislation to reduce the emission of these air pollutants, power plants in particular have installed "flue gas desulfurization systems" also known as scrubbers.

Application

Wet flue gas desulfurization or scrubber systems are an excellent way of reducing the sulfur dioxide emissions caused by coal combustion boilers. The flue gas discharged from the boiler is fed into the absorber. In the absorber, a mixture of water and pulverized limestone is sprayed on the flue gas. The limestone slurry absorbs the sulfur dioxide (SO2) contained in the flue gas reducing the emission of sulfur. The limestone reacts with the SO2 to produce calcium sulfite.

Flue Gas Desulfurization Systems 2The calcium sulfite then reacts with oxygen and is then finally removed as gypsum. The limestone slurry and gypsum slurry are very abrasive. Magnetic flowmeters are normally used to measure and control the flow of the limestone slurry to the sprayers.

Conventional style PTFE-lined magnetic flowmeters used in such applications normally have a short life expectancy, due to the abrasiveness of the slurry. The use of non-retained liners and electrodes that expose their seal to the process fluid/slurry make the meters prone to fail. Once the liner wears away or the seal around the electrode is eroded, the process fluid can then attack the meter's internals (coils and electrode wiring).

Also, the use of electrodes that protrude into the process can create an increase in slurry noise as the limestone or gypsum collide with the electrode. In slurries, noise (voltage) is generated when solid substances collide with the electrode. Conventional electronics cannot distinguish the noise from the true flow signal and thus the flowmeter's output is erratic and the signal is not suitable for control purposes.

Photo A: Example of liner wear at low velocities. 
Photo A: Example of liner wear at low
velocities. Because of the retained
liner design, this meter continued to
function.

Incorrect installation of the meter can also contribute to problems for magnetic flowmeters. In addition to the typical installation consideration for upstream and downstream straight runs, maintaining the velocity of the slurry within certain limits is also important.

If the flow rate is too low, below 1.5 m/sec (5 ft/sec), the solids (limestone) can fall out of suspension. In a horizontal line this can cause the bottom of the meter to wear out at an excessive rate (see photo A). If the flow rate is too high, greater than 2 m/sec (7 ft/sec), the limestone can cause increased wear on the liner. Should any of these conditions occur the life of the meter will be greatly decreased.

A Solution

ADMAG AXF magnetic flowmeters from Yokogawa have been specified for such applications. Since these flowmeters use retained liners and insertion style electrodes that remove the sealing surface from the process fluid, service life is enhanced.

The potential for slurry noise due to the limestone and gypsum colliding with the electrode is reduced due to ADMAG's flush electrode design.

In addition, ADMAG's dual-frequency excitation and further optional enhanced dual frequency excitation provides stable and accurate measurement due to a high frequency sampling rate and an ability to filter out slurry noise.

ADMAGAn ideal installation for the measurement of a limestone slurry is to have the flow running up and to have the operating velocity between 1.5 to 3 m/sec (5 to 10 ft/sec). This keeps the limestone suspended in the water and the wear on the liner to a minimum.

The use of a metal hat earth ring can also reduce erosion of the liner by protecting the leading edge of the liner. Where these installation recommendations cannot be met, a ceramic lined meter should be considered.

The ADMAG ceramic meter would be well suited for such applications due to the abrasion resistance of its liner and the reduction of slurry noise due to the flush and fused platinum electrode. Further, the ADMAG CA, capacitance type magnetic flowmeter, which is ceramic lined and has no wetted electrodes, offers solutions for abrasion resistance and immunity to slurry noise.

Related Products & Solutions

  • ADMAG AXF

    The AXF magnetic flow meter is a sophisticated product with outstanding reliability and ease of operation, developed on the basis of decades of field experience. Based on FOUNDATION™ fieldbus specifications, AXF Fieldbus Magnetic Flow meter models offer more flexible instrumentation.

    See More
  • ADMAG CA

    ADMAG CA magnetic flow meter is excellent at measurement in ultra-low conductivity fluids down to 0.01 microS/cm, adhesive fluids, or slurry fluids.

    See More
×

Have Questions?

Contact a Yokogawa Expert to learn how we can help you solve your challenges.


Top