ADMAG AXR Two-wire Magnetic Flowmeters
The ADMAG AXR is the world’s first two-wire magnetic flowmeter which employs the fluid noise free “Dual Frequency Excitation Method,” achieving excellent stability for instrumentation.
ADMAG AXR Two-wire Magnetic Flowmeters
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Features: ADMAG AXR Two-wire Magnetic Flowmeters
| High Performance and Excellent Functionality | ||
|
Field-proven dual frequency, now by 2-wire magmeter |
||
| The "Dual Frequency Excitation Method" combines two strengths: stability in flow measurement due to low frequency excitation and high noise resistance due to high frequency excitation. Therefore, the method is strong against fluctuations of fluid condition and is ideal for stable measurement. | ||
| High Accuracy | ||
| The ADMAG AXR performs 0.5% of rate under normal flowrate conditions. | ||
| Reducing the Instrumentation Cost | ||
|
Direct Connection with the DCS |
||
| AC power sources are not necessary. The ADMAG AXR can be connected with almost all distributors, signal conditioner cards, and input modules. | ||
| Energy Saving | ||
| Compared with four-wire magnetic flowmeters, the ADMAG AXR can drastically decrease power consumption ( 1 to 4 % ). | ||
| User-friendly Functionality | ||
|
Enhanced Diagnostic Function |
||
| By checking the level of the insulating substance on the electrodes, it is possible to determine when maintenance is required. | ||
| Clear and Versatile Indications | ||
| The full dot-matrix LCD indicator facilitates various displays such as one to three lines and multi-lingual display. In an alarm condition, a full description of the countermeasure is indicated. |
||
| Parameter Setting | ||
| Magnet switches and push switches are employed. Magnet switches enable parameters to be set without opening the case cover in the hazardous area. |
||
Specifications: ADMAG AXR Two-wire Magnetic Flowmeters
| Structure | Integral flowmeter | |||||||
| Excitation Method | Dual frequency excitation | |||||||
| Nominal Pipe Size [Unit : mm (approx. inch)] |
General-purpose use: 25 (1.0) to 100 (4.0) Explosion proof Type: 25 (1.0) to 100 (4.0) |
|||||||
| Supply Voltage | Operating voltage range 14.7 to 35 V DC Two-wire system | |||||||
| Output Signals | Current output Digital output(One output can be selected from pulse, alarm or status outputs.) |
|||||||
| Electrode Material | Stainless steel-JIS SUS316L (AISI 316L SS/EN 1.4404 equivalent), Hastelloy C276 equivalent, Tantalum, Platinum-iridium | |||||||
| Fluid Temp. | - 40 to 130 deg.C (- 40 to 266 deg.F) [ depends on model type ] | |||||||
| Ambient Temp. | - 40 to 55 deg.C (- 40 to 131 deg.F) | |||||||
| Accuracy | 0.5% of rate (Note 1) [ depends on nominal pipe size and fluid condition ] |
|||||||
| Fluid Conductivity | 10 micro-S/cm or larger (note 2) [ depends on nominal pipe size and fluid condition ] |
|||||||
| Lining | Fluorocarbon PFA (Mirror-finished lining surface) | |||||||
| Lay Length [Unit : mm (approx. inch)] |
|
|||||||
| Indicator | Full dot-matrix LCD | |||||||
| Operational Switch | 4 magnet switches (including push switches) | |||||||
| Self Diagnosis | Electrode adhesion diagnosis, Coil open, etc. | |||||||
| Alarm Message | Alarm message with countermeasure is indicated ( English, German, French, Italian, Spanish, Japanese ) |
|||||||
| Options | Direction change of the electrical connection, Special Gaskets, Bar-magnet for operation of magnet switches, etc. |
|||||||
* Please refer to General Specifications in detail.
| Note 1: | The accuracy of a product before shipment is defined as totalized value at the result of calibration test in our water actual flow test facility. |
| Note 2: | For a fluid with large flow noise (pure water, pure alcohol or others), or a fluid with low conductivity and low viscosity, the output fluctuates and is impossible to measure accurately. |