Standard |
Multi-Variable |
Reduced Bore |
| Model & code |
DY Vortex Flowmeter |
Optional code:/MV |
Option code:/R1,
/R2 (Release in the end of September) |
| Fluid to be measured |
Liquid, gas, steam (avoid multiphase flow and sticky fluids) |
| Nominal size |
15mm ∼ 300mm
(400mm:special) |
25mm ∼ 200mm |
25mm ∼ 200mm |
| Accuracy |
Liquid: ±1.0% of reading(20000≤Re≤10ˆ3)
Liquid: ±0.75% of reading(D×10ˆ3≤Re) |
Liquid: ±1.0% of reading
(20000≤Re≤10ˆ3) |
Gas, steam: ±1.0% of reading (flow velocity less than 35m/s)
Gas, steam: ±1.5% of reading (flow velocity 35m/s~80m/s) |
| Output signal |
Simultaneous output(both analog and transistor contact output available) |
| Process temperature range |
-29 deg C ∼ 260 deg C(standard)
-196 deg C ∼ 100 deg C(option: cryogenic version)
-29 deg C ∼ 450 deg C(option: high process temperature version) |
| Process pressure limit |
-0.1MPa (-1kg/cm2) to flange rating |
| Ambient temperature |
-29 to 85 deg C (Integral type / No indicator)
-29 to 80 deg C (Integral type / with indicator) -29 to 85 deg C (Remote type detector) -40 to 85 deg C (Remote type converter / No indicator) -30 to 80 deg C (Remote type converter / with indicator) |
| Ambient humidity |
5~100%RH( Non-condensing) |
| Mounting |
Integral type and Remote type detector: Flange mounting or wafer mounting Remote type converter: 2 inch pipe mounting
JIS10/20/40、ANSI150/300/600/900, JPI150/300/600,DIN PN10/16/25/40 |
| Electrical connection |
JIS G1/2 female, ANSI 1/2NPT female, ISO M20×1.5 female |
| Explosion protected type |
TIIS F.P., FM E.P./I.S., CENELEC ATEX(KEMA) E.P./I.S./type n,
CSA E.P./I.S., SAA E.P./I.S., SAA E.P./I.S. |
| Material |
Body: SCS14A cast stainless steel (equivalent to SUS316,CF8M)
Shedder bar: duplex stainless steel (option:anti-corrosion version)
Gasket: SUS316 stainless steel with polytetrafluoroethylene (Teflon) coating
Converter housing and case cover: aluminum alloy |