Measurement of Concentration of Supersaturated NaCl Solution in Salt Dissolvers at Electrolysis Plants

Introduction

Control of sodium chloride (NaCl) concentration at a salt dissolver where solid salt is dissolved in water, is highly important because of the electrolysis efficiency. A conventional way of measuring the concentration of supersaturated NaCl solution had been performed by using non-contact type sensors (e.g., γ-ray density meter) since NaCl, impurities, and precipitates are in the solution. In this way, there were disadvantages such as troublesome maintenance and therefore, the radiation control is required for γ-ray density meter. Responding to these backgrounds, the FLXA202 2-wire inductive conductivity analyzer provides concentration reading and realizes to improve substantial maintainability, cost performance and measurement accuracy.

Caustic Soda Production Process

Caustic Soda Production Process

Expected Benefits

  • Measures NaCl concentration in salt dissolvers
  • Reduces operating costs

Process Overview

In an electrolysis plant, the solid salt is dissolved in water in a salt dissolver to make brine. This brine contains impurities, such as calcium, magnesium or sulfates, that decrease electrolysis efficiency. The brine is purified by removing these impurities before being fed to an electrolyzer, where the purified brine is electrolyzed to produce caustic soda and chlorine. The caustic soda solution produced at the cathode in the electrolyzer is concentrated in a multiple effect evaporator, as a result the concentration is increased from approximately 32% to 48%.

Solution Details

Measurement system

2-wire inductive conductivity system

Sensor ISC40G(J)-GG-T1-☐☐
Flow-through holder ISC40FF(J)-PJ
Transmitter FLXA202-D-BーD-☐-C5-NN-A-N-LA-☐-NN

2-wire inductive conductivity system

Inductive Conductivity Sensor & Transmitter Installation Diagram

Utilities

FLXA202 2-wire inductive conductivity analyzer
Power supply voltage: 17 - 40 V DC (from distributor)
Power consumption: 0.9 VA maximum
PH201G distributor
Power supply:
100 V: 20 to130 V DC/80 to 138 V AC, 47 to 63 Hz
220 V: 120 to 340 V DC/138 to 264 V AC, 47 to 63 Hz
Power consumption: 24 V DC: approx. 200 mA
100 V AC: approx. 7 VA
220 V AC: approx. 11 VA

Notes

Sampling should be done in the supernatant liquid in a salt dissolver. The supernatant liquid is collected in a settling tank and then the supernatant liquid of the tank is transported to a measurement tank where the sensor is installed.

Field Data

1. Process conditions (salt dissolver)

Temperature: Approx. 65°C
Pressure: Atmospheric pressure
Sample: Supersaturated brine
NaCl concentration control range: 200 to 360 g/L
--> 18.1 to 30 wt%*

* Depends on user's actual data of specific gravity.

2. FLXA202 setting parameters

Relationship between conductivity and concentration is based
on the linear approximation of S = 16.3x that is obtained by actual measurement using SC72 Personal Conductivity Meter.

  • NaCl temperature compensation table is used
  • Reference temperature setting: 25°C
Concentration (%) Conductivity (mS/cm)
18 293
24 391
30 489

Industrias

  • Especialidades y productos químicos finos

    Yokogawa ha servido durante mucho tiempo a los clientes en el mercado de productos químicos de especialidad y finos. Con una solución por lotes líder en el mercado que ofrece la mejor fiabilidad de clase y flexibilidad, así como expertos de la industria que entienden los complejos requisitos en el diseño de una solución por lotes, puede estar seguro de que en su asociación con Yokogawa tendrá un sistema que le permitirá producir productos que satisfagan las necesidades de sus clientes en el futuro, mientras mantiene la seguridad y el cumplimiento normativo.

    Leer Más
  • Química

    Las plantas químicas dependen de procesos de producción continua y por lotes, cada una de los cuales impone diferentes exigencias para un sistema de control. Un proceso continuo exige un sistema de control robusto y estable que no falle y provoque el cierre de una línea de producción, mientras que en un proceso por lotes el énfasis se centra en tener un sistema de control que permita una gran flexibilidad para realizar ajustes a fórmulas, procedimientos y otros elementos. Ambos tipos de sistemas necesitan ser administrados en el historial de calidad del producto disponible, así como tener la capacidad de ejecutar operaciones no rutinarias. Con el respaldo de su extenso portafolio de productos, un equipo de experimentados ingenieros en sistemas y una red global de ventas y servicio, Yokogawa ofrece una solución para cada proceso productivo.

    Leer Más
×

 

 

¿Tiene Dudas?

Contacte a un Experto de Yokogawa y conozca como podemos ayudarle a resolver sus retos.


Top