Measurement of Concentration of Supersaturated NaCl Solution in Salt Dissolvers at Electrolysis Plants

Introduction

Control of sodium chloride (NaCl) concentration at a salt dissolver where solid salt is dissolved in water, is highly important because of the electrolysis efficiency. A conventional way of measuring the concentration of supersaturated NaCl solution had been performed by using non-contact type sensors (e.g., γ-ray density meter) since NaCl, impurities, and precipitates are in the solution. In this way, there were disadvantages such as troublesome maintenance and therefore, the radiation control is required for γ-ray density meter. Responding to these backgrounds, the FLXA202 2-wire inductive conductivity analyzer provides concentration reading and realizes to improve substantial maintainability, cost performance and measurement accuracy.

Caustic Soda Production Process

Caustic Soda Production Process

Expected Benefits

  • Measures NaCl concentration in salt dissolvers
  • Reduces operating costs

Process Overview

In an electrolysis plant, the solid salt is dissolved in water in a salt dissolver to make brine. This brine contains impurities, such as calcium, magnesium or sulfates, that decrease electrolysis efficiency. The brine is purified by removing these impurities before being fed to an electrolyzer, where the purified brine is electrolyzed to produce caustic soda and chlorine. The caustic soda solution produced at the cathode in the electrolyzer is concentrated in a multiple effect evaporator, as a result the concentration is increased from approximately 32% to 48%.

Solution Details

Measurement system

2-wire inductive conductivity system

Sensor ISC40G(J)-GG-T1-☐☐
Flow-through holder ISC40FF(J)-PJ
Transmitter FLXA202-D-BーD-☐-C5-NN-A-N-LA-☐-NN

2-wire inductive conductivity system

Inductive Conductivity Sensor & Transmitter Installation Diagram

Utilities

FLXA202 2-wire inductive conductivity analyzer
Power supply voltage: 17 - 40 V DC (from distributor)
Power consumption: 0.9 VA maximum
PH201G distributor
Power supply:
100 V: 20 to130 V DC/80 to 138 V AC, 47 to 63 Hz
220 V: 120 to 340 V DC/138 to 264 V AC, 47 to 63 Hz
Power consumption: 24 V DC: approx. 200 mA
100 V AC: approx. 7 VA
220 V AC: approx. 11 VA

Notes

Sampling should be done in the supernatant liquid in a salt dissolver. The supernatant liquid is collected in a settling tank and then the supernatant liquid of the tank is transported to a measurement tank where the sensor is installed.

Field Data

1. Process conditions (salt dissolver)

Temperature: Approx. 65°C
Pressure: Atmospheric pressure
Sample: Supersaturated brine
NaCl concentration control range: 200 to 360 g/L
--> 18.1 to 30 wt%*

* Depends on user's actual data of specific gravity.

2. FLXA202 setting parameters

Relationship between conductivity and concentration is based
on the linear approximation of S = 16.3x that is obtained by actual measurement using SC72 Personal Conductivity Meter.

  • NaCl temperature compensation table is used
  • Reference temperature setting: 25°C
Concentration (%) Conductivity (mS/cm)
18 293
24 391
30 489

相关行业

  • 化工

    化工产品是现代生活和工业不可或缺的组成部分。生产这些产品的化工厂需要全年365天、每天24小时保持稳定运行,同时实现高水平的安全性、生产效率和可持续性。横河电机凭借逾百年的测量与控制专业经验,结合人工智能(AI)等数字技术,助力化工行业客户实现可持续增长。携手横河电机,共塑制造运营的未来。

相关产品&解决方案

  • pH和ORP分析仪

    pH和ORP流量计、分析仪和变送器用于pH和ORP的连续过程监测,以确保水/产品质量,如监测污水排放、批量中和、浆料存储、洗涤塔,冷却塔、化学品、水/废水处理和许多其他应用。

  • 两线制变送器/分析仪FLXA21

    FLEXA™ 系列分析仪用于工业装置中的连续在线测量。可选配单传感器或双传感器测量,是现有非常灵活的两线制分析仪。

  • 电导率传感器

    电导率传感器和电极用于测量过程电导率、电阻率、WIFI、软化水、RO水、百分比浓度、锅炉水排污和TDS。有伸缩式、流通式、浸入式和直插式等多种安装选项。选择合适的电极/传感器对优化测量结果至关重要。


置顶
WeChat QR Code
横河电机(中国)有限公司