Category Sitemap
Home / Our Businesses / Test & Measurement / Products / Digital Oscilloscopes /
Digital Oscilloscopes

DL9040/ DL9140/ DL9240 Series
Accessories
PBA2500
PBA2500 2.5 GHz active probe (701913)
Use this 10:1 active probe with the DL9240 series to realize system measurements up to 1.5 GHz BW.

Bandwidth: DC to 2.5 GHz (-3 dB)
Attenuation: 10:1 (±2%)
Input resistance: 100 kΩ (±2%)
Input capacitance: approx 0.9 pF (typ.)
Dynamic range: ±7 V
Max. input voltage: ±25 V DC + AC peak
Offset voltage: ±10 V
PBA1500
PBA1500 1.5 GHz active probe (701914)
Use this 10:1 active probe with the DL9140 series to realize system measurements up to 1.0 GHz BW.

Bandwidth: DC to 1.5 GHz (-3 dB)
Attenuation: 10:1 (±2%)
Input resistance: 100 kΩ (±2%)
Input capacitance: approx 0.9 pF (typ.)
Dynamic range: ±7 V
Max. input voltage: ±25 V DC + AC peak
Offset voltage: ±10 V
PBA1000
PBA1000 1.0 GHz active probe (701912)
Use this 10:1 active probe with the DL9040 series to realize system measurements up to 500 MHz BW.

Bandwidth: DC to 1.0 GHz (-3 dB)
Attenuation: 10:1 (±2%)
Input resistance: 100 kΩ (±2%)
Input capacitance: approx 0.9 pF (typ.)
Dynamic range: ±7 V
Max. input voltage: ±25 V DC + AC peak
Offset voltage: ±10 V
PBL5000
PBL5000 5 GHz low capacitance probe (701974)
This 10:1 and 20:1 (selectable) passive probe is used with the 50 ohm input setting on the DL9000. The change in attenuation is realized by changing resistance on the tip of the probe.

Bandwidth: DC to 5 GHz (-3 dB)
Attenuation: 10:1 or 20:1 (±2%)
Input resistance: 450 Ω or 950 Ω (±2%)
Input capacitance: approx 0.25 pF (typ. 450 Ω), 0.4 pF (typ. 950 Ω)
Max. input voltage: 20 Vrms
PBDH1000
PBDH1000 1.0 GHz differential probe (701924) New!
This probe can be used in combination with the DL9000 or SB5000 series.

Input Resistance: 1 MΩ
                        (against GND level from each input terminal)
Input Capacitance: approx. 1.1 pF
                        (against GND level from each input terminal)
Max. operational input voltage: ±35 V
Max. differential input voltage: ±25 V
Attenuation: 1/50
PBD2000
PBD2000 2.0 GHz differential probe (701923)
Use this 10:1 differential probe with the DL9000 to realize system differential measurements up to 1.5 GHz BW.

Input Resistance: approx. 50 kΩ
                       (against GND level from each input terminal)
Input Capacitance: approx. 1.1 pF
                       (against GND level from each input terminal)
Max. operational input voltage: ±7 V
Max. differential input voltage: ±5 V
Attenuation: 1/10
                         more
701915
701915 Browser attachments
This attachment set can be used with PBA2500 and PBD2000.

Spring pin (straight) x 4
Spring pin (angle) x 4
Pin (straight) x 20
Pin (angle) x 20
Pin (L shape) x 2
Micro Clip (black) x 1
Micro Clip (red) x 1
Single lead (black) x 1
Single lead (red) x 1
PB500
PB500 500 MHz passive probe (701943)
This probe can be used for general purpose day-to-day measurements up to 500 MHz BW. The DL9000 series comes standard with foure PB500 probes.

Attenuation: 10:1 (±2%)(When used with the DL9000)
Input resistance: 10 MΩ ±2%
Input capacitance: approx 14 pF (typ.) (When used with the DL9000)
Max. Input range: ±600 V DC + AC peak
701975
701975 50 ohm DC block
This DC block can be used to remove the DC component from an incoming signal. Use this block if you want to remove bias voltage from reaching the PBL5000 probe.
701920
701920 500 MHz differential probe
For differential signal measurements. Order the DL9000 with the /P2 option to directly power the probe off the scope.

Attenuation: 10:1 (±3%)
Input resistance (typ.)100 kΩ
Input capacitance (typ.) 2.5 pF
Max. allowable differential voltage: ±12 V DC + AC peak
Max. common mode voltage: ±30 V DC + AC peak
701928
PBC100 100 MHz Current Probe (701928) New!  
This probe doesn’t need an extra power connection (LEMO connector), can be recognized automatically and adjust zero position from the operation of the DL9000 series.

Bandwidth: DC to 100 MHz (-3 dB)
Max. continuous input range: 30 Arms, 50 A peak
701932
701932 100MHz current probe
Clamp-type current probe. Order the DL9000 with the /P2 option to directly power the probe off the scope.

Bandwidth: DC to 100 MHz (-3 dB)
Max. continuous input range: 30 Arms, 50 A peak
701929
PBC050 50 MHz Current Probe (701929) New!
This probe doesn’t need an extra power connection (LEMO connector), can be recognized automatically and adjust zero position from the operation of the DL9000 series.

Bandwidth: DC to 50 MHz (-3 dB)
Max. continuous input range: 30 Arms, 50 A peak
701933
701933 50MHz current probe
Clamp-type current probe. Order the DL9000 with the /P2 option to directly power the probe off the scope.

Bandwidth: DC to 50 MHz (-3 dB)
Max. continuous input range: 30 Arms, 50 A peak
701942
701942 Miniature Passive Probe
Bandwidth: DC to 350MHz (-3dB)
Attenuation ratio: 1/10 (Fixed)
Maximum input voltage: 400Vrms
Cable length: 3m
701944
701944 100:1 Probe
Bandwidth: DC to 400MHz (-3dB)
Attenuation ratio: 1/100 (Fixed)
Maximum input voltage: 1,000Vrms, 6,000Vpeak
Cable length: 1.2m
701945
701945 100:1 Probe
Bandwidth: DC to 250MHz (-3dB)
Attenuation ratio: 1/100 (Fixed)
Maximum input voltage: 1,000Vrms, 6,000Vpeak
Cable length: 3m
GLOBAL  
YOKOGAWA

Powered by Ultraseek
·  DL9040/ DL9140/ DL9240 Series
See Also...
DL Series Selection Guide