Category Sitemap
Home / Our Businesses / Test & Measurement / Products / Digital Oscilloscopes /
Digital Oscilloscopes

DL1720E/ DL1735E/ DL1740E/ DL1740EL
Features
  1 2 3 4  
Long Memory and Easy Zoom FunctionAll-Points Display and Fast Screen UpdatesSmart Search Function
History Memory and History SearchMeasuring Periodically Fluctuating AmplitudesHow can I quickly count a large number of pulses in a waveform?
Envelope and Roll modesSimple and Enhanced TriggersGO/NO GO Judgment
Dedicated I²C Bus Trigger and Analysis FunctionDedicated SPI Bus Trigger and Analysis FunctionUSB
EthernetOutputting and Viewing Screen ImagesRear Panel
Simple and Enhanced Triggers for Reliable Capturing of a Variety of Waveforms
Simple and Enhanced Triggers
Action-On Trigger
With the action-on trigger, a specified action is automatically executed each time the trigger is activated. You can use the trigger for a variety of actions, such as automatically saving captured data. The action-on trigger is useful for purposes such as collecting data in continuous rests.
GO/NO GO Judgment -Automatic Waveform Discrimination-
GO/NO GO Judgment
GO/NO GO Judgment
Select zones or paramenters for the waveform of an acquired signal. The DL1700E judges the signal being measured and automatically takes action. Actions you can choose from include: outputting screen images data to the destination specified in the Copy Setup menu, saving waveform data in the medium specified in the File menu, sounding the buzzer, and sending e-mail.

 I²C Bus Analysis Function (Optional)

Triggers can be activated using conditions such as Start, Non-Ack, Address pattern, and Data pattern. These dedicated I²C bus triggers can also be combined with other analog signals to activate additional triggers. I2C bus trigger setuo menu
I²C bus trigger setup menu

 I²C Bus Analysis Function (Optional)

Captured waveforms can be analyzed in a time series manner, and the analysis results displayed in a list. When an analysis result is selected with the cursor, the corresponding waveform is automatically enlarged in the zoom area. Two pairs of I²C busses can be input at the same time, then analysis can be performed alternately on either bus. I2C bus analysis results
I²C bus analysis results
The SPI data bus is a synchronous 8-bit serial bus used widely for inter-IC and data communications in embedded systems. SPI bus signals can be captured using the DL1700E dedicated triggers and the waveforems can be analyzed and displayed on the screen.
  SPI bus analysis setting screen
SPI bus analysis setting screen

SPI Bus Trigger Function (optional)

Triggers can be activated by comparing each byte of MOSI (master output slave input) and MISO (master input slave output) data with specified conditions. You can trigger on user-defined strings of data from 1 to 8 bytes long.

SPI Bus Analysis Function (optional)

Data analysis results and SS (slave select) bits can be displayed in a list together with the waveforms. You can perform a high speed search for a specified MOSI or MISO data pattern (of 1 to 8 bytes) from within all of the captured data.


Products Home Specifications Software Testimonials Accessories
Viewing PDF files requires Adobe Reader.
GLOBAL  
YOKOGAWA

Powered by Ultraseek
·  DL1720E/ DL1735E/ DL1740E/ DL1740EL
See Also...
DL Series Selection Guide
Find the right one for you!
more
Serial Bus Analyzer Selection Guide
For I2C, CAN, and SPI analysis
more
Probes for Digital Oscilloscopes
Supporting a variety of measurement
more
Accessories for DL series
Accessories other than probes
more
FAQ
For the DL series
more
  1 2 3 4