Category Sitemap
Home / Our Businesses / Test & Measurement / Products / Digital Oscilloscopes /
Probes for Digital Oscilloscopes
Differential Probes
Yokogawa’s differential probes let you make wide-bandwidth differential measurements. Just connect the output of the probe to the input of a single-ended digital oscilloscope. We provide you a variety of differential probes, which can be utilized for measuring the gate-to-source voltage of a switching power supply, read/write signals of a hard disk drive, high-speed logic signals, CAN bus signals, and more.

y-Link RFQ Request a quote y-Link Contact us General questions y-Link Worldwide network Where to buy?   y-Link Document library Accessories Catalog Download
700924
700924 100 MHz Differential Probe
With increases in the speed of measured signals in recent years, it has become necessary to make floating measurements over a wide frequency band. The 700924 differential probe lets you make wide-band (100 MHz) differential input measurements by just connecting the probe to the input of a single-end input digital oscilloscope.
701920
701920 500 MHz Differential Probe
Accurately observe high-speed differential signals
701923
701923 2.0 GHz Differential Probe (PBD2000)
This probe can be used in combination with the DL9000 or SB5000 series.
Bandwidth: DC to 2.0 GHz (-3 dB)
Input Resistance: 50 kΩ
                        (against GND level from each input terminal)
Input Capacitance: approx. 1.1 pF
                        (against GND level from each input terminal)
Max. operational input voltage: ±7 V
Max. differential input voltage: ±5 V
Attenuation: 1/10
701924
701924 1.0 GHz Differential Probe (PBDH1000) New!
This probe can be used in combination with the DL9000 or SB5000 series.

Bandwidth: DC to 1.0 GHz (-3 dB)
Input Resistance: 1 MΩ
                        (against GND level from each input terminal)
Input Capacitance: approx. 1.1 pF
                        (against GND level from each input terminal)
Max. operational input voltage: ±35 V
Max. differential input voltage: ±25 V
Attenuation: 1/50
700925
700925 15 MHz Differential Probe
Bandwidth: DC to 15 MHz (-3 dB)

Input attenuation ratio: switch between 1/10, 1/100
Maximum allowed differential voltage:
  ±500V (DC+ACpeak) or 350 Vrms (1/100)
Maximum common mode input voltage:
  ±500V (DC+ACpeak) or 350 Vrms (1/10, 1/100)
701921
701921 100 MHz Differential Probe
Bandwidth: DC to 100 MHz (-3 dB)
Input attenuation ratio: switch between 1/10 and 1/100
Maximum allowed differential voltage:
  ±700 V (DC+ACpeak, 1/100)
Maximum common mode input voltage:
  ±700 V (DC+ACpeak) (1/10, 1/100)
701922
701922 200 MHz Differential Probe
Bandwidth: DC to 200 MHz (-3 dB)
Input attenuation ratio: 1/10 (fixed)
Maximum allowed differential voltage: ±20 V (DC+ACpeak)
Maximum common mode input voltage: ±60 V (DC+ACpeak)
50 Ω output
B9852MJ
B9852MJ Power cable
The B9852MJ cable supplies power to the 700924, 700925 and 701921 differential probes* from the DL probe power con-nectors. (The probe power option is re-quired on the DL unit.)

* Cable only works with newer 700924, 700925 and 701921 probes that indicate "6VDC or 9VDC"at the probe input power connector.
700976
700976 50 Ω terminator
Used to connect an oscilloscope hav-ing a 1M-ohm input to a probe with a 50-ohm output. It is required when us-ing the 701920 and 701922 probes with the DL1600 series.
Another probes and Accessories
Viewing PDF files requires Adobe Reader.
GLOBAL  
YOKOGAWA

Powered by Ultraseek
·  Probes for Digital Oscilloscopes
See Also...
DL Series Selection Guide
Find the right one for you!
more
Serial Bus Analyzer Selection Guide
For I2C, CAN, and SPI analysis
more
Probes for Digital Oscilloscopes
Supporting a variety of measurement
more
Accessories for DL series
Accessories other than probes
more
FAQ
For the DL series
more
Top of this page