Category Sitemap
Home / Our Businesses / Test & Measurement / Products / Digital Oscilloscopes /
Digital Oscilloscopes

Serial Bus Analyzer
· I2C Bus CAN Bus SPI Bus FlexRay
I2C Bus
Serial Bus Analyzer - I2C -
DL7440/DL7480
DL7440/DL7480
DL1740E/EL
DL1740E/EL
DL1640/DL1640L
DL1640/DL1640L
DL9140/DL9240
DL9040/DL9140/DL9240
Triggering
  Trigger Setup Menu
Trigger Setup Menu

The trigger types are Start trigger, Non–Ack trigger and Address trigger.  Combination triggers with these I2C bus trigger types can be set using analog signals on other channels.

Analysis

Acquired waveforms are analyzed in a time series, and analyzed results are decoded and displayed one byte at a time.  When a cursor is moved over the onscreen data, the corresponding waveform is automatically enlarged in the zoom area.

Waveform and Analysis Results
Waveform and Analysis Results
Search

You can search rapidly for a specified addresses and data pattern in the analyzed results.  When the specified data are found, the cursors automatically move to the corresponding location, and the waveform is enlarged in the zoom area.

  DL7440/DL7480 DL1740E/DL1740EL DL1640/DL1640L DL9040/DL9140/DL9240
Max. sampling rate 2 GS/s 1 GS/s 200 MS/s 5 GS/s / 10 GS/s
Analog bandwidth 500 MHz 500 MHz 200 MHz 500 MHz/1 GHz/1.5 GHz
Max. memory length 16 MW 8 MW 32 MW 6.25 MW
I2C trigger type Start/Non-ACK/Address & Data I2C trigger type
Address & data: trigger on combination of assigned address & data pattern
Non-Ack: trigger on non acq condition
Every start: trigger on start condition
General Call: trigger on general call and the followingbyte
Start byte / HS mode: trigger on Start byte and HS mode
"Data 1" pattern for address &
data trigger
・1 byte
・Immediately after "Address"
・1 byte
・Immediately after "address" or "anywhere"
"Data 2" pattern for address &
data trigger
・1 byte or 2 bytes
・The "first byte" after number of byte count, or "anywhere" after number of byte count from Data1
N.A.
Combination trigger I2C Only, I2C on Pattern, I2C -> Pattern
Analysis results
(waveform & analysis)
Start/Stop, Data#, analysis results (Hex), Ack Simple or Detailed display
Analysis results (details) Start/Stop, Data No., Time from the Reference point, Analysis results (Binary, Hex), Ack
Number of analyzable bytes 40,000 40,000
Applicable bus Bus transfer rate: Max. 3.4 Mbps
Address mode: 7 bit
SM bus: Complies with System Management Bus
7 bit > 7/10 bit
Search Search for specified Address/Data/Ack
GLOBAL  
YOKOGAWA

Powered by Ultraseek
·  Serial Bus Analyzer
See Also...
DL Series Selection Guide
Find the right one for you!
more
Serial Bus Analyzer Selection Guide
For I2C, CAN, and SPI analysis
more
Probes for Digital Oscilloscopes
Supporting a variety of measurement
more
Accessories for DL series
Accessories other than probes
more
FAQ
For the DL series
more
Top of this page