DL7440/DL7480 |
DL1740E/DL1740EL |
DL1640/DL1640L |
DL9040/DL9140/DL9240 |
| Max. sampling rate |
2 GS/s |
1 GS/s |
200 MS/s |
5 GS/s / 10 GS/s |
| Analog bandwidth |
500 MHz |
500 MHz |
200 MHz |
500 MHz/1 GHz/1.5 GHz |
| Max. memory length |
16 MW |
8 MW |
32 MW |
6.25 MW |
| I2C trigger type |
Start/Non-ACK/Address & Data |
I2C trigger type
Address & data: trigger on combination of assigned address & data pattern
Non-Ack: trigger on non acq condition
Every start: trigger on start condition
General Call: trigger on general call and the followingbyte
Start byte / HS mode: trigger on Start byte and HS mode |
"Data 1" pattern for address &
data trigger |
・1 byte
・Immediately after "Address" |
・1 byte
・Immediately after "address" or "anywhere" |
"Data 2" pattern for address &
data trigger |
・1 byte or 2 bytes
・The "first byte" after number of byte count, or "anywhere" after number of byte count from Data1 |
N.A. |
| Combination trigger |
I2C Only, I2C on Pattern, I2C -> Pattern |
Analysis results
(waveform & analysis) |
Start/Stop, Data#, analysis results (Hex), Ack |
Simple or Detailed display |
| Analysis results (details) |
Start/Stop, Data No., Time from the Reference point, Analysis results (Binary, Hex), Ack |
| Number of analyzable bytes |
40,000 |
40,000 |
| Applicable bus |
Bus transfer rate: Max. 3.4 Mbps
Address mode: 7 bit
SM bus: Complies with System Management Bus |
7 bit > 7/10 bit |
| Search |
Search for specified Address/Data/Ack |